EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dynamic Gait Stability Estimated Using One or Two Inertial Measurement Units Worn on the Human Body

Haoyun Peng, Shogo Okamoto iD, Hiroki Watanabe, Yasuhiro Akiyama iD

Sensors · 12.02.2026 · 26 (4) · 1211

DOI: 10.3390/s26041211 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 12.02.2026. Verfasst von Haoyun Peng und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Science, Tokyo Metropolitan University, 6-6 Asahigaoka, Hino, Tokyo 191-0065, Japan. Hauptthemen laut MEDLINE: Gait, Postural Balance. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Okawa Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The margin of stability (MoS) is a metric used to assess dynamic postural stability during walking. Although MoS is typically computed from optical motion capture data, previous studies have shown that MoS can be approximated from six-axis kinematic signals—linear acceleration and angular velocity—measured by inertial measurement units (IMUs). With IMU-equipped devices such as smartphones and smartwatches becoming widespread, it is increasingly common for individuals to carry two or more such devices in daily life. This study aimed to identify combinations of two body locations that most effectively predict MoS. IMU sensors were attached to ten body locations while participants walked on a treadmill. Principal motion analysis, a reductive regression method for multidimensional time-series data, was employed for MoS prediction, and cross-validation was used for reliable model evaluation. Appropriate combinations of two IMU sensors achieved mean errors of approximately 30 mm and 11 mm in anterior and mediolateral MoS, respectively, compared with reference values derived from optical motion capture. These errors were comparable to the intrinsic standard deviations of MoS, suggesting that IMU-based MoS estimation is sufficiently accurate for the classification of individuals at high fall risk.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GaitPostural BalanceHumansMotion CaptureBiomechanical PhenomenaWalkingMaleFemaleAdultAcceleration

Stichwörter der Autor:innen

margin of stabilitymotion synergyprincipal motion analysis

Autor:innen und Institutionen

  • Department of Computer Science, Tokyo Metropolitan University, 6-6 Asahigaoka, Hino, Tokyo 191-0065, Japan.
  • Department of Mechanics and Robotics, Shinshu University, 3-15-1 Tokita, Ueda, Nagano 386-8567, Japan.

ORCID-Profile: Shogo Okamoto, Yasuhiro Akiyama

Förderung

  • Okawa Foundation

Zitieren

APA

Peng, H., Okamoto, S., Watanabe, H., & Akiyama, Y. (2026). Dynamic Gait Stability Estimated Using One or Two Inertial Measurement Units Worn on the Human Body. Sensors, 26(4), 1211. https://doi.org/10.3390/s26041211

Vancouver

Peng H, Okamoto S, Watanabe H, Akiyama Y. Dynamic Gait Stability Estimated Using One or Two Inertial Measurement Units Worn on the Human Body. Sensors. 2026;26(4):1211. doi:10.3390/s26041211

BibTeX
@article{Peng2026,
  author = {Peng, Haoyun and Okamoto, Shogo and Watanabe, Hiroki and Akiyama, Yasuhiro},
  title = {Dynamic Gait Stability Estimated Using One or Two Inertial Measurement Units Worn on the Human Body},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {4},
  pages = {1211},
  doi = {10.3390/s26041211}
}
Kostenlos starten →