Accurate Measurement of Blast Shock Wave Pressure by Enhanced Sensor System Based on Neural Network
Sensors · 06.10.2025 · 25 (19) · 6187
DOI: 10.3390/s25196187 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 06.10.2025. Verfasst von Fan Yang und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Automation, Wuxi University, Wuxi 214105, China. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Anhui Province Higher Education Scientific Research Project, Opening Project of Key Laboratory of Power Electronics and Motion Control of Anhui Higher Education Institutions, Natural Science Research Project for Universities in Jiangsu Province.
Abstract (Originalsprache)
During blast shock wave pressure measurement, strong mechanical vibrations and shocks can affect the dynamic characteristics of shock wave pressure sensors, introducing measurement errors. To improve measurement accuracy for the compression phase, a specialized buffer device was designed to enhance the sensor’s dynamic response to transient pressure rises. Using a double-diaphragm shock tube, the dynamic calibration of the enhanced sensor system was carried out and the influence of the buffer device on the dynamic performance was investigated. A mathematical model based on a backpropagation (BP) neural network was developed to characterize the sensor system, and a dynamic compensation method was implemented to improve the enhanced shock wave pressure sensor system. Experimental results demonstrated that while the buffer device significantly reduced the operational bandwidth of the sensor system, the BP neural network-based dynamic compensation effectively widened the bandwidth and improved measurement accuracy. This research provides a practical solution for high-precision dynamic pressure measurement, specifically targeting the compression phase in complex environments.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Automation, Wuxi University, Wuxi 214105, China.
- Department of Basic Courses, Wuxi University, Wuxi 214105, China.
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
- School of Electrical and Information Engineering, Anhui University of Technology, Ma'anshan 243002, China.
- Anhui Provincial Key Laboratory of Power Electronics and Motion Control, Anhui University of Technology, Ma'anshan 243002, China.
Förderung
- Anhui Province Higher Education Scientific Research Project
- Opening Project of Key Laboratory of Power Electronics and Motion Control of Anhui Higher Education Institutions
- Natural Science Research Project for Universities in Jiangsu Province
- Opening Project of the Key Laboratory of Power Electronics and Motion Control of Anhui Higher Education Institutions
Zitieren
APA
Yang, F., Zhu, H., Kong, D., & Zhao, C. (2025). Accurate Measurement of Blast Shock Wave Pressure by Enhanced Sensor System Based on Neural Network. Sensors, 25(19), 6187. https://doi.org/10.3390/s25196187
Vancouver
Yang F, Zhu H, Kong D, Zhao C. Accurate Measurement of Blast Shock Wave Pressure by Enhanced Sensor System Based on Neural Network. Sensors. 2025;25(19):6187. doi:10.3390/s25196187
BibTeX
@article{Yang2025,
author = {Yang, Fan and Zhu, Hongzhen and Kong, Deren and Zhao, Chuanrong},
title = {Accurate Measurement of Blast Shock Wave Pressure by Enhanced Sensor System Based on Neural Network},
journal = {Sensors},
year = {2025},
volume = {25},
number = {19},
pages = {6187},
doi = {10.3390/s25196187}
}