EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Shock Wave Pressure Measurement and Calibration Method Based on Bar Pressure Sensor

Yong-Xiang Shi iD, Ying-Cheng Peng iD, Yuan-Ding Xing iD, Xue-Jie Jiao iD, Xiao-Fei Huang iD, Ze-Qun Ba iD

Sensors · 01.08.2025 · 25 (15) · 4743

DOI: 10.3390/s25154743 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 01.08.2025. Verfasst von Yong-Xiang Shi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Northwest Institute of Nuclear Technology, Xi'an 710024, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In order to correctly measure the shock wave pressure generated by a near-field explosion, and while considering the limitations of the measurement and calibration method of the current bar pressure sensor, an improved shock wave pressure measurement method was designed based on a bar pressure sensor combined with photon Doppler velocimetry (PDV) and strain measurement. By measuring the strain on the pressure bar and the particle velocity on the rear-end face, the shock wave pressure applied on the front-end face of the pressure bar was calculated based on one-dimensional stress wave theory. On the other hand, a calibration method was designed to validate the reliability of the test system. Based on the split-Hopkinson pressure bar (SHPB) loading experiment, the transmission characteristics of stress wave in the bar and the accuracy of the system test results were verified. The results indicated that the stress wave measurement results were consistent with the one-dimensional elementary theoretical calculation results of stress wave propagation in different wave-impedance materials, and the peak deviation measured by PDV and strain measurement method was less than 1.5%, which proved the accuracy of the test method and the feasibility of the calibration method.

Schlagwörter

Stichwörter der Autor:innen

bar pressure sensorshock wavestrain measurement

Autor:innen und Institutionen

  • Northwest Institute of Nuclear Technology, Xi'an 710024, China.

ORCID-Profile: Yong-Xiang Shi, Ying-Cheng Peng, Yuan-Ding Xing, Xue-Jie Jiao, Xiao-Fei Huang, Ze-Qun Ba

Zitieren

APA

Shi, Y. X., Peng, Y. C., Xing, Y. D., Jiao, X. J., Huang, X. F., & Ba, Z. Q. (2025). Shock Wave Pressure Measurement and Calibration Method Based on Bar Pressure Sensor. Sensors, 25(15), 4743. https://doi.org/10.3390/s25154743

Vancouver

Shi YX, Peng YC, Xing YD, Jiao XJ, Huang XF, Ba ZQ. Shock Wave Pressure Measurement and Calibration Method Based on Bar Pressure Sensor. Sensors. 2025;25(15):4743. doi:10.3390/s25154743

BibTeX
@article{Shi2025,
  author = {Shi, Yong-Xiang and Peng, Ying-Cheng and Xing, Yuan-Ding and Jiao, Xue-Jie and Huang, Xiao-Fei and Ba, Ze-Qun},
  title = {Shock Wave Pressure Measurement and Calibration Method Based on Bar Pressure Sensor},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {15},
  pages = {4743},
  doi = {10.3390/s25154743}
}
Kostenlos starten →