EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Analytical Model of Motion Artifacts in a Measured Arterial Pulse Signal—Part II: Tactile Sensors

Md Mahfuzur Rahman iD, Subodh Toraskar iD, Mamun Hasan, Zhili Hao iD

Sensors · 12.09.2025 · 25 (18) · 5700

DOI: 10.3390/s25185700 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 12.09.2025. Verfasst von Md Mahfuzur Rahman und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Aerospace Engineering, Old Dominion University, Norfolk, VA 23529, USA. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper, the second of two parts, presents an analytical model of motion artifacts (MA) in measured pulse signals by a tactile sensor, which contains a deformable microstructure sitting on a substrate. While the tissue-contact-sensor (TCS) stack and the sensor are both treated as a 1DOF (degree-of-freedom) system, tissue–sensor contact joins their mass together to form a 1DOF system with springs and dampers on both sides. MA on the sensor substrate causes baseline drift and time-varying system parameters (TVSP) of the TCS stack simultaneously. An analytical model is developed to mathematically relate baseline drift and TVSP to a measured pulse signal. The numerical calculation is conducted in MATLAB. Baseline drift in a measured pulse signal is much lower than the actual MA in its measurement. As compared to baseline drift, TVSP generates relatively abrupt, small distortion (e.g., 0.2% variation in heart rate and

Schlagwörter

Stichwörter der Autor:innen

TCS stackarterial pulse measurementbaseline driftdynamic systemsmotion artifactstactile sensorstime-varying system parameters (TVSP)

Autor:innen und Institutionen

  • Department of Mechanical and Aerospace Engineering, Old Dominion University, Norfolk, VA 23529, USA.

ORCID-Profile: Md Mahfuzur Rahman, Subodh Toraskar, Zhili Hao

Zitieren

APA

Rahman, M. M., Toraskar, S., Hasan, M., & Hao, Z. (2025). An Analytical Model of Motion Artifacts in a Measured Arterial Pulse Signal—Part II: Tactile Sensors. Sensors, 25(18), 5700. https://doi.org/10.3390/s25185700

Vancouver

Rahman MM, Toraskar S, Hasan M, Hao Z. An Analytical Model of Motion Artifacts in a Measured Arterial Pulse Signal—Part II: Tactile Sensors. Sensors. 2025;25(18):5700. doi:10.3390/s25185700

BibTeX
@article{Rahman2025,
  author = {Rahman, Md Mahfuzur and Toraskar, Subodh and Hasan, Mamun and Hao, Zhili},
  title = {An Analytical Model of Motion Artifacts in a Measured Arterial Pulse Signal—Part II: Tactile Sensors},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {18},
  pages = {5700},
  doi = {10.3390/s25185700}
}
Kostenlos starten →