A Prototype of a Lightweight Structural Health Monitoring System Based on Edge Computing
Sensors · 09.09.2025 · 25 (18) · 5612
DOI: 10.3390/s25185612 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 09.09.2025. Verfasst von Yinhao Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil Engineering, Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming 650500, China. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Yunnan Fundamental Research Projects, National Natural Science Foundation of China.
Abstract (Originalsprache)
Bridge Structural Health Monitoring (BSHM) is vital for assessing structural integrity and operational safety. Traditional wired systems are limited by high installation costs and complexity, while existing wireless systems still face issues with cost, synchronization, and reliability. Moreover, cloud-based methods for extreme event detection struggle to meet real-time and bandwidth constraints in edge environments. To address these challenges, this study proposes a lightweight wireless BSHM system based on edge computing, enabling local data acquisition and real-time intelligent detection of extreme events. The system consists of wireless sensor nodes for front-end acceleration data collection and an intelligent hub for data storage, visualization, and earthquake recognition. Acceleration data are converted into time–frequency images to train a MobileNetV2-based model. With model quantization and Neural Processing Unit (NPU) acceleration, efficient on-device inference is achieved. Experiments on a laboratory steel bridge verify the system’s high acquisition accuracy, precise clock synchronization, and strong anti-interference performance. Compared with inference on a general-purpose ARM CPU running the unquantized model, the quantized model deployed on the NPU achieves a 26× speedup in inference, a 35% reduction in power consumption, and less than 1% accuracy loss. This solution provides a cost-effective, reliable BSHM framework for small-to-medium-sized bridges, offering local intelligence and rapid response with strong potential for real-world applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Civil Engineering, Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming 650500, China.
- Intelligent Infrastructure Operation and Maintenance Technology Innovation Team, Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming 650500, China.
- Yunnan Transportation Science Research Institute Co., Ltd., Kunming 650200, China.
ORCID-Profile: Zhiyi Tang, Xiaomin Huang
Förderung
- Yunnan Fundamental Research Projects
- National Natural Science Foundation of China
Zitieren
APA
Wang, Y., Tang, Z., Qian, G., Xu, W., Huang, X., & Fang, H. (2025). A Prototype of a Lightweight Structural Health Monitoring System Based on Edge Computing. Sensors, 25(18), 5612. https://doi.org/10.3390/s25185612
Vancouver
Wang Y, Tang Z, Qian G, Xu W, Huang X, Fang H. A Prototype of a Lightweight Structural Health Monitoring System Based on Edge Computing. Sensors. 2025;25(18):5612. doi:10.3390/s25185612
BibTeX
@article{Wang2025,
author = {Wang, Yinhao and Tang, Zhiyi and Qian, Guangcai and Xu, Wei and Huang, Xiaomin and Fang, Hao},
title = {A Prototype of a Lightweight Structural Health Monitoring System Based on Edge Computing},
journal = {Sensors},
year = {2025},
volume = {25},
number = {18},
pages = {5612},
doi = {10.3390/s25185612}
}
EUVIMED