EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Arc Dynamics and Erosion Behavior of Pantograph-Catenary Contacts Under Controlled Humidity Levels

Bingquan Li, Yijian Zhao iD, Ran Ji, Huajun Dong, Ningning Wei iD

Sensors · 21.08.2025 · 25 (16) · 5208

DOI: 10.3390/s25165208 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 21.08.2025. Verfasst von Bingquan Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Dalian Jiaotong University, Dalian 116028, China. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Scientific Research Project of Liaoning Provincial Department of Education, Scientific Research Project of the Liaoning Provincial Department of Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In response to the instability fluctuations and erosion characteristic changes in pantograph-catenary system (PCS) arcs induced by humidity variations in an open environment, a single-variable controlled experimental approach based on multi-source data fusion is proposed. This study innovatively establishes a humidity-controlled reciprocating current-carrying arc initiation test platform, integrating digital image processing with the dynamic analysis of multi-physics sensor signals (current, voltage, temperature). The study quantitatively evaluates the arc motion characteristics and the erosion effects on the frictional contact pair under different relative humidity levels (30%, 50%, 70%, and 90%) with a DC power supply (120 V/25 A). The experimental data and analysis reveal that increasing humidity results in higher contact resistance and accumulated arc energy, with arc stability first improving and then decreasing. At low humidity, arc behavior is more intense, and the erosion rate is faster. As humidity increases, the electrode wear transitions from adhesive wear to electrochemical wear, accompanied by copper transfer. The results suggest that the arc stability is optimal at moderate humidity (50% RH), with a peak current-carrying efficiency of 66% and a minimum loss rate of 14.5%. This threshold offers a vital theoretical framework for the optimization and risk assessments of PCS design.

Schlagwörter

Stichwörter der Autor:innen

arc dynamics characteristicsarc erosioncurrent-carryingimage processingrelative humidity

Autor:innen und Institutionen

  • School of Mechanical Engineering, Dalian Jiaotong University, Dalian 116028, China.
  • Department of Railway Rolling Stock, Liaoning Railway Vocational and Technical College, Jinzhou 121000, China.

ORCID-Profile: Yijian Zhao, Ningning Wei

Förderung

  • National Natural Science Foundation of China
  • Scientific Research Project of Liaoning Provincial Department of Education
  • Scientific Research Project of the Liaoning Provincial Department of Education

Zitieren

APA

Li, B., Zhao, Y., Ji, R., Dong, H., & Wei, N. (2025). Arc Dynamics and Erosion Behavior of Pantograph-Catenary Contacts Under Controlled Humidity Levels. Sensors, 25(16), 5208. https://doi.org/10.3390/s25165208

Vancouver

Li B, Zhao Y, Ji R, Dong H, Wei N. Arc Dynamics and Erosion Behavior of Pantograph-Catenary Contacts Under Controlled Humidity Levels. Sensors. 2025;25(16):5208. doi:10.3390/s25165208

BibTeX
@article{Li2025,
  author = {Li, Bingquan and Zhao, Yijian and Ji, Ran and Dong, Huajun and Wei, Ningning},
  title = {Arc Dynamics and Erosion Behavior of Pantograph-Catenary Contacts Under Controlled Humidity Levels},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {16},
  pages = {5208},
  doi = {10.3390/s25165208}
}
Kostenlos starten →