EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Activity Type Effects Signal Quality in Electrocardiogram Devices

Bryndan Lindsey iD, Samantha Snyder iD, Yuanyuan Zhou iD, Jae Kun Shim, Jin-Oh Hahn iD, William Evans, Joel Martin iD

Sensors · 20.08.2025 · 25 (16) · 5186

DOI: 10.3390/s25165186 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 20.08.2025. Verfasst von Bryndan Lindsey und 6 weiteren Autor:innen. Beteiligte Einrichtung: Johns Hopkins Applied Physics Laboratory (JHU/APL), Laurel, MD 20723, USA. Hauptthemen laut MEDLINE: Electrocardiography, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrocardiogram (ECG) devices are commonly used to monitor heart rate (HR) and heart rate variability (HRV), but their signal quality under non-upright or torso-dominant activities may suffer due to motion artifact and interference from surrounding musculature. We compared ECG signal quality during treadmill walking, circuit training, and an obstacle course using three chest-worn commercial devices (Polar H10, Equivital EQ-02, and Zephyr BioHarness 3.0) and a multi-lead ECG monitor (BIOPAC). Signal quality was quantified using the beat signal quality index (SQI), and HR data were rejected if SQI fell below 0.7 or if values were physiologically implausible. Signal rejection rate was calculated as the proportion of low-quality observations across device and activity type. Significant effects of both device (p < 0.001) and activity (p < 0.001) were observed, with greater signal rejection during the obstacle course and circuit training compared to treadmill walking (p < 0.01). The Zephyr exhibited significantly higher rejection rates than the Polar (p = 0.018) and BIOPAC (p = 0.017), while the Polar showed lower average rejection rates across all activities. These findings underscore the importance of including dynamic, non-upright tasks in ECG validation protocols and suggest that certain commercial devices may be more robust under realistic conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographySignal Processing, Computer-AssistedHumansHeart RateMaleAdultFemaleWalkingArtifactsExercise Test

Stichwörter der Autor:innen

ECG signal qualityelectrocardiogrammotion artifactphysiological monitoringwearable ECG devices

Autor:innen und Institutionen

  • Johns Hopkins Applied Physics Laboratory (JHU/APL), Laurel, MD 20723, USA.
  • Orthopedics and Sports Medicine, MedStar Health Research Institute, Baltimore, MD 21218, USA.
  • Department of Mechanical Engineering, University of Maryland, College Park, MD 20742, USA.
  • Department of Exercise Science, Elon College, College of Arts & Sciences, Elon University, Elon, NC 27244, USA.
  • Center for the Advancement of Well-Being, George Mason University, Fairfax, VA 22030, USA.
  • Sports Medicine Assessment Research & Testing (SMART) Laboratory, George Mason University, Manassas, VA 20110, USA.

ORCID-Profile: Bryndan Lindsey, Samantha Snyder, Yuanyuan Zhou, Jin-Oh Hahn, Joel Martin

Zitieren

APA

Lindsey, B., Snyder, S., Zhou, Y., Shim, J. K., Hahn, J. O., Evans, W., & Martin, J. (2025). Activity Type Effects Signal Quality in Electrocardiogram Devices. Sensors, 25(16), 5186. https://doi.org/10.3390/s25165186

Vancouver

Lindsey B, Snyder S, Zhou Y, Shim JK, Hahn JO, Evans W, et al. Activity Type Effects Signal Quality in Electrocardiogram Devices. Sensors. 2025;25(16):5186. doi:10.3390/s25165186

BibTeX
@article{Lindsey2025,
  author = {Lindsey, Bryndan and Snyder, Samantha and Zhou, Yuanyuan and Shim, Jae Kun and Hahn, Jin-Oh and Evans, William and Martin, Joel},
  title = {Activity Type Effects Signal Quality in Electrocardiogram Devices},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {16},
  pages = {5186},
  doi = {10.3390/s25165186}
}
Kostenlos starten →