EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Three-Dimensional Printed Stimulating Hybrid Smart Bandage

Małgorzata A Janik iD, Michał Pielka iD, Petro Kovalchuk iD, Michał Mierzwa iD, Paweł Janik iD

Sensors · 2025

DOI: 10.3390/s25165090 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Małgorzata A Janik und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Engineering, Faculty of Science and Technology, University of Silesia in Katowice, 41-205 Sosnowiec, Poland. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Bandages. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The treatment of chronic wounds and pressure sores is an important challenge in the context of public health and the effectiveness of patient treatment. Therefore, new methods are being developed to reduce or, in extreme cases, to initiate and conduct the wound healing process. This article presents an innovative smart bandage, programmable using a smartphone, which generates small amplitude impulse vibrations. The communication between the smart bandage and the smartphone is realized using BLE. The possibility of programming the smart bandage allows for personalized therapy. Owing to the built-in MEMS sensor, the smart bandage makes it possible to monitor work during rehabilitation and implement an auto-calibration procedure. The flexible, openwork mechanical structure of the dressing was made in 3D printing technology, thanks to which the solution is easy to implement and can be used together with traditional dressings to create hybrid ones. Miniature electronic circuits and actuators controlled by the PWM signal were designed as replaceable elements; thus, the openwork structure can be treated as single-use. The smart bandage containing six actuators presented in this article generates oscillations in the range from about 40 Hz to 190 Hz. The system generates low-amplitude vibrations, below 1 g. The actuators were operated at a voltage of 1.65 V to reduce energy consumption. For comparison, the actuators were also operated at the nominal voltage of 3.17 V, as specified by the manufacturer.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalBandagesHumansSmartphoneWound HealingVibrationEquipment Design

Stichwörter der Autor:innen

IoTembedded systemmobilesmartwearablewound healing

Autor:innen und Institutionen

  • Institute of Biomedical Engineering, Faculty of Science and Technology, University of Silesia in Katowice, 41-205 Sosnowiec, Poland.

ORCID-Profile: Małgorzata A Janik, Michał Pielka, Petro Kovalchuk, Michał Mierzwa, Paweł Janik

Zitieren

APA

Janik, M. A., Pielka, M., Kovalchuk, P., Mierzwa, M., & Janik, P. (2025). Three-Dimensional Printed Stimulating Hybrid Smart Bandage. Sensors. https://doi.org/10.3390/s25165090

Vancouver

Janik MA, Pielka M, Kovalchuk P, Mierzwa M, Janik P. Three-Dimensional Printed Stimulating Hybrid Smart Bandage. Sensors. 2025. doi:10.3390/s25165090

BibTeX
@article{Janik2025,
  author = {Janik, Małgorzata A and Pielka, Michał and Kovalchuk, Petro and Mierzwa, Michał and Janik, Paweł},
  title = {Three-Dimensional Printed Stimulating Hybrid Smart Bandage},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25165090}
}
Kostenlos starten →