Design and Analysis of an Autonomous Active Ankle–Foot Prosthesis with 2-DoF
Sensors · 2025
DOI: 10.3390/s25164881 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Sayat Akhmejanov und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Robotics and Technical Tools of Automation, Satbayev University, Almaty 050013, Kazakhstan. Hauptthemen laut MEDLINE: Prosthesis Design, Ankle, Foot, Artificial Limbs. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science Committee of the Ministry of Science and Higher Education of the Republic of Kazakhstan.
Abstract (Originalsprache)
This paper presents the development, modeling, and analysis of an autonomous active ankle prosthesis with two degrees of freedom (2-DoF), designed to reproduce movements in the sagittal (dorsiflexion/plantarflexion) and frontal (inversion/eversion) planes in order to enhance the stability and naturalness of the user’s gait. Unlike most commercial prostheses, which typically feature only one active degree of freedom, the proposed device combines a lightweight mechanical design, a screw drive with a stepper motor, and a microcontroller-based control system. The prototype was developed using CAD modeling in SolidWorks 2024, followed by dynamic modeling and finite element analysis (FEA). The simulation results confirmed the achievement of physiological angular ranges of ±20–22 deg. in both planes, with stable kinematic behavior and minimal vertical displacements. According to the FEA data, the maximum von Mises stress (1.49 × 108 N/m2) and deformation values remained within elastic limits under typical loading conditions, though cyclic fatigue and impact energy absorption were not experimentally validated and are planned for future work. The safety factor was estimated at ~3.3, indicating structural robustness. While sensor feedback and motor dynamics were idealized in the simulation, future work will address real-time uncertainties such as sensor noise and ground contact variability. The developed design enables precise, energy-efficient, and adaptive motion control, with an estimated average power consumption in the range of 7–9 W and an operational runtime exceeding 3 h per charge using a standard 18,650 cell pack. These results highlight the system’s potential for real-world locomotion on uneven surfaces. This research contributes to the advancement of affordable and functionally autonomous prostheses for individuals with transtibial amputation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Robotics and Technical Tools of Automation, Satbayev University, Almaty 050013, Kazakhstan.
- Department of Electronic Engineering, Almaty University of Power Engineering and Telecommunications, Almaty 050013, Kazakhstan.
- Department of Automation and Control, Mukhametzhan Tynyshbayev ALT University, Almaty 050013, Kazakhstan.
ORCID-Profile: Sayat Akhmejanov, Nursultan Zhetenbayev, Algazy Zhauyt, Yerkebulan Nurgizat, Abu-Alim Ayazbay, Arman Uzbekbayev
Förderung
- Science Committee of the Ministry of Science and Higher Education of the Republic of Kazakhstan
Zitieren
APA
Akhmejanov, S., Zhetenbayev, N., Sultan, A., Zhauyt, A., Nurgizat, Y., Ozhikenov, K., Ayazbay, A. A., & Uzbekbayev, A. (2025). Design and Analysis of an Autonomous Active Ankle–Foot Prosthesis with 2-DoF. Sensors. https://doi.org/10.3390/s25164881
Vancouver
Akhmejanov S, Zhetenbayev N, Sultan A, Zhauyt A, Nurgizat Y, Ozhikenov K, et al. Design and Analysis of an Autonomous Active Ankle–Foot Prosthesis with 2-DoF. Sensors. 2025. doi:10.3390/s25164881
BibTeX
@article{Akhmejanov2025,
author = {Akhmejanov, Sayat and Zhetenbayev, Nursultan and Sultan, Aidos and Zhauyt, Algazy and Nurgizat, Yerkebulan and Ozhikenov, Kassymbek and Ayazbay, Abu-Alim and Uzbekbayev, Arman},
title = {Design and Analysis of an Autonomous Active Ankle–Foot Prosthesis with 2-DoF},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25164881}
}
EUVIMED