Design and preliminary verification of a novel powered ankle–foot prosthesis: From the perspective of lower-limb biomechanics compared with ESAR foot
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0303397 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Jingjing Liu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Applied Biomechanics, Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia. Hauptthemen laut MEDLINE: Artificial Limbs, Prosthesis Design, Foot. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Ministry of Science, Technology, and Innovation, Malaysia.
Abstract (Originalsprache)
A novel powered ankle–foot prosthesis is designed. The effect of wearing the novel prosthesis and an energy-storage-and-return (ESAR) foot on lower-limb biomechanics is investigated to preliminarily evaluate the design. With necessary auxiliary materials, a non-amputated subject (a rookie at using prostheses) is recruited to walk on level ground with an ESAR and the novel powered prostheses separately. The results of the stride characteristics, the ground reaction force (GRF) components, kinematics, and kinetics in the sagittal plane are compared. Wearing the powered prosthesis has less prolongation of the gait cycle on the unaffected side than wearing the ESAR foot. Wearing ESAR or proposed powered prostheses influences the GRF, kinematics, and kinetics on the affected and unaffected sides to some extent. Thereinto, the knee moment on the affected side is influenced most. Regarding normal walking as the reference, among the total of 15 indexes, the influences of wearing the proposed powered prosthesis on six indexes on the affected side (ankle’s/knee’s/hip’s angles, hip’s moment, and Z- and X-axis GRF components) and five indexes on the unaffected side (ankle’s/knee’s/hip’s angles and ankle’s/hip’s moments) are slighter than those of wearing the ESAR foot. The influences of wearing the powered prosthesis on two indexes on the unaffected side (knee’s moment and X-axis GRF component) are similar to those of wearing the ESAR foot. The greatest improvement of wearing the powered prosthesis is to provide further plantarflexion after reaching the origin of the ankle joint before toe-off, which means that the designed powered device can provide further propulsive power for the lifting of the human body’s centre of gravity during walking on level ground. The results demonstrate that wearing the novel powered ankle–foot prosthesis benefits the rookie in recovering the normal gait more than wearing the ESAR foot.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Centre for Applied Biomechanics, Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia.
- School of Mechanical Engineering and Mechanics, Xiangtan University, Xiangtan, Hunan, China.
- Centre for Sports and Exercise Science, Universiti Malaya, Kuala Lumpur, Malaysia.
- Department of Mechanical Engineering, University of Vermont, Burlington, Vermont, United States of America.
- The Chancellery, Universiti Tenaga Nasional, Kajang, Malaysia.
ORCID-Profile: Jingjing Liu, Selina X Yao
Förderung
- the Ministry of Science, Technology, and Innovation, Malaysia
Zitieren
APA
Liu, J., Liu, J., Cheah, P. Y., Al Kouzbary, M., Al Kouzbary, H., Yao, S. X., Shasmin, H. N., Arifin, N., Razak, N. A. A., & Abu Osman, N. A. (2024). Design and preliminary verification of a novel powered ankle–foot prosthesis: From the perspective of lower-limb biomechanics compared with ESAR foot. PLOS ONE. https://doi.org/10.1371/journal.pone.0303397
Vancouver
Liu J, Liu J, Cheah PY, Al Kouzbary M, Al Kouzbary H, Yao SX, et al. Design and preliminary verification of a novel powered ankle–foot prosthesis: From the perspective of lower-limb biomechanics compared with ESAR foot. PLOS ONE. 2024. doi:10.1371/journal.pone.0303397
BibTeX
@article{Liu2024,
author = {Liu, Jingjing and Liu, Jingang and Cheah, Pei Yi and Al Kouzbary, Mouaz and Al Kouzbary, Hamza and Yao, Selina X and Shasmin, Hanie Nadia and Arifin, Nooranida and Razak, Nasrul Anuar Abd and Abu Osman, Noor Azuan},
title = {Design and preliminary verification of a novel powered ankle–foot prosthesis: From the perspective of lower-limb biomechanics compared with ESAR foot},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0303397}
}
EUVIMED