Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Emily Acampora und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering and Science, Florida Institute of Technology, 150 W University Blvd, Melbourne, FL 32901, USA. Hauptthemen laut MEDLINE: Electroencephalography, Blinking, Textiles, Brain. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Florida Space Grant Consortium.
Abstract (Originalsprache)
Background
Electroencephalography (EEG) systems based on textile electrodes are increasingly being developed to address the need for more wearable sensor systems for brain function monitoring. Blink-related oscillations (BROs) are a new measure of brain function that corresponds to brainwave responses occurring after spontaneous blinking, and indexes neural processes as the brain evaluates new visual information appearing after eye re-opening. Prior studies have reported BRO utility as both a clinical and non-clinical biomarker of cognition, but no study has demonstrated BRO measurement using textile-based EEG devices that facilitate user comfort for real-world applications.
Methods
We investigated BRO measurement using a four-channel EEG system with textile electrodes by extracting BRO responses using existing, publicly available EEG data (n = 9). We compared BRO effects derived from textile-based electrodes with those from standard dry Ag/Ag-Cl electrodes collected at the same locations (i.e., Fp1, Fp2, F7, F8) and using the same EEG amplifier.
Results
Results showed that BRO effects measured using textile electrodes exhibited similar features in both time and frequency domains compared to dry Ag/Ag-Cl electrodes. Data from both technologies also showed similar performance in artifact removal and signal capture.
Conclusions
These findings provide the first demonstration of successful BRO signal capture using four-channel EEG with textile electrodes, providing compelling evidence toward the development of a comfortable and user-friendly EEG technology that uses the simple activity of blinking for objective brain function assessment in a variety of settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering and Science, Florida Institute of Technology, 150 W University Blvd, Melbourne, FL 32901, USA.
ORCID-Profile: Emily Acampora
Förderung
- Florida Space Grant Consortium
Zitieren
APA
Acampora, E., Ghosh Hajra, S., & Liu, C. C. (2025). Measuring Blink-Related Brainwaves Using Low-Density Electroencephalography with Textile Electrodes for Real-World Applications. Sensors. https://doi.org/10.3390/s25144486
Vancouver
Acampora E, Ghosh Hajra S, Liu CC. Measuring Blink-Related Brainwaves Using Low-Density Electroencephalography with Textile Electrodes for Real-World Applications. Sensors. 2025. doi:10.3390/s25144486
BibTeX
@article{Acampora2025,
author = {Acampora, Emily and Ghosh Hajra, Sujoy and Liu, Careesa Chang},
title = {Measuring Blink-Related Brainwaves Using Low-Density Electroencephalography with Textile Electrodes for Real-World Applications},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25144486}
}
EUVIMED