EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dynamical Embedding of Single-Channel Electroencephalogram for Artifact Subspace Reconstruction

Doli Hazarika iD, K N Vishnu, Ramdas Ransing, Cota Navin Gupta iD

Sensors · 2024

DOI: 10.3390/s24206734 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Doli Hazarika und 3 weiteren Autor:innen. Beteiligte Einrichtung: Neural Engineering Lab, Department of Biosciences and Bioengineering, Indian Institute of Technology, Guwahati 781039, India. Hauptthemen laut MEDLINE: Electroencephalography, Artifacts, Algorithms, Blinking. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NEWGEN-IEDC, DST, Govt. of India, MoE doctoral scholarship, Government of India.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study introduces a novel framework to apply the artifact subspace reconstruction (ASR) algorithm on single-channel electroencephalogram (EEG) data. ASR is known for its ability to remove artifacts like eye-blinks and movement but traditionally relies on multiple channels. Embedded ASR (E-ASR) addresses this by incorporating a dynamical embedding approach. In this method, an embedded matrix is created from single-channel EEG data using delay vectors, followed by ASR application and reconstruction of the cleaned signal. Data from four subjects with eyes open were collected using Fp1 and Fp2 electrodes via the CameraEEG android app. The E-ASR algorithm was evaluated using metrics like relative root mean square error (RRMSE), correlation coefficient (CC), and average power ratio. The number of eye-blinks with and without the E-ASR approach was also estimated. E-ASR achieved an RRMSE of 43.87% and had a CC of 0.91 on semi-simulated data and effectively reduced artifacts in real EEG data, with eye-blink counts validated against ground truth video data. This framework shows potential for smartphone-based EEG applications in natural environments with minimal electrodes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroencephalographyArtifactsAlgorithmsBlinkingSignal Processing, Computer-AssistedHumansElectrodesSmartphone

Stichwörter der Autor:innen

artifact removalartifact subspace reconstructionelectroencephalographyeye blinksignal processingsingle channelsmartphone

Autor:innen und Institutionen

  • Neural Engineering Lab, Department of Biosciences and Bioengineering, Indian Institute of Technology, Guwahati 781039, India.
  • Department of Psychiatry, Clinical Neurosciences, and Addiction Medicine, All India Institute of Medical Sciences, Guwahati 781101, India.

ORCID-Profile: Doli Hazarika, Cota Navin Gupta

Förderung

  • NEWGEN-IEDC, DST, Govt. of India
  • MoE doctoral scholarship
  • Government of India
  • NEWGEN-IEDC

Zitieren

APA

Hazarika, D., Vishnu, K. N., Ransing, R., & Gupta, C. N. (2024). Dynamical Embedding of Single-Channel Electroencephalogram for Artifact Subspace Reconstruction. Sensors. https://doi.org/10.3390/s24206734

Vancouver

Hazarika D, Vishnu KN, Ransing R, Gupta CN. Dynamical Embedding of Single-Channel Electroencephalogram for Artifact Subspace Reconstruction. Sensors. 2024. doi:10.3390/s24206734

BibTeX
@article{Hazarika2024,
  author = {Hazarika, Doli and Vishnu, K N and Ransing, Ramdas and Gupta, Cota Navin},
  title = {Dynamical Embedding of Single-Channel Electroencephalogram for Artifact Subspace Reconstruction},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24206734}
}
Kostenlos starten →