EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Monitoring Nasal Breathing Using an Adjustable FBG Sensing Unit

Xiyan Yan, Yan Feng, Min Xu, Hua Zhang

Sensors · 2025

DOI: 10.3390/s25134060 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Xiyan Yan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Robotics Institute, School of Mechanical and Automotive Engineering, Shanghai University of Engineering Science, Shanghai 201620, China. Hauptthemen laut MEDLINE: Respiration, Nose. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China under Grant, Shanghai Local Colleges and Universities Capacity Building Plan, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We have developed an adjustable optical fiber Bragg grating (FBG) sensing unit for monitoring nasal breathing. The FBG sensing unit can accommodate individuals with varying facial dimensions by adjusting the connecting holes of the ear hangers. We employed two FBG configurations: an encapsulated FBG within a silicon tube (FBG1) and a bare FBG (FBG2). Calibration experiments show the temperature sensitivities of 6.77 pm/°C and 6.18 pm/°C, respectively, as well as the pressure sensitivities of 2.05 pm/N and 1.18 pm/N, respectively. We conducted breathe monitoring tests on male and female volunteers under the resting and the motion states. For the male volunteer, the breathing frequency is 13.48 breaths per minute during the rest state and increases to 23.91 breaths per minute during the motion state. For the female volunteer, the breathing frequency is 14.12 breaths per minute during rest and rises to 24.59 breaths per minute during motion. Experimental results show that the FBG sensing unit can effectively distinguish breathing rate for the same person in different states. In addition, we employed a random forest algorithm to assess the importance of two sensors in breathing monitoring applications. The findings indicate that FBG1 outperforms FBG2 in monitoring performance, highlighting that pressure plays a positive impact in enhancing the accuracy of breathing monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RespirationNoseHumansFemaleMaleMonitoring, PhysiologicRespiratory RateAdultOptical FibersAlgorithms

Stichwörter der Autor:innen

adjustable FBG sensing unitbreathing frequencynasal breathingrandom forest

Autor:innen und Institutionen

  • Robotics Institute, School of Mechanical and Automotive Engineering, Shanghai University of Engineering Science, Shanghai 201620, China.
  • Shanghai Large-Scale Component Intelligent Manufacturing Robot Technology Collaborative Innovation Center, Shanghai 201620, China.
  • School of Information Engineering, Shanghai Zhongqiao Vocational and Technical University, Shanghai 201514, China.

Förderung

  • National Natural Science Foundation of China under Grant
  • Shanghai Local Colleges and Universities Capacity Building Plan
  • National Natural Science Foundation of China

Zitieren

APA

Yan, X., Feng, Y., Xu, M., & Zhang, H. (2025). Monitoring Nasal Breathing Using an Adjustable FBG Sensing Unit. Sensors. https://doi.org/10.3390/s25134060

Vancouver

Yan X, Feng Y, Xu M, Zhang H. Monitoring Nasal Breathing Using an Adjustable FBG Sensing Unit. Sensors. 2025. doi:10.3390/s25134060

BibTeX
@article{Yan2025,
  author = {Yan, Xiyan and Feng, Yan and Xu, Min and Zhang, Hua},
  title = {Monitoring Nasal Breathing Using an Adjustable FBG Sensing Unit},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25134060}
}
Kostenlos starten →