Monitoring Nasal Breathing Using an Adjustable FBG Sensing Unit
Sensors · 2025
DOI: 10.3390/s25134060 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Xiyan Yan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Robotics Institute, School of Mechanical and Automotive Engineering, Shanghai University of Engineering Science, Shanghai 201620, China. Hauptthemen laut MEDLINE: Respiration, Nose. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China under Grant, Shanghai Local Colleges and Universities Capacity Building Plan, National Natural Science Foundation of China.
Abstract (Originalsprache)
We have developed an adjustable optical fiber Bragg grating (FBG) sensing unit for monitoring nasal breathing. The FBG sensing unit can accommodate individuals with varying facial dimensions by adjusting the connecting holes of the ear hangers. We employed two FBG configurations: an encapsulated FBG within a silicon tube (FBG1) and a bare FBG (FBG2). Calibration experiments show the temperature sensitivities of 6.77 pm/°C and 6.18 pm/°C, respectively, as well as the pressure sensitivities of 2.05 pm/N and 1.18 pm/N, respectively. We conducted breathe monitoring tests on male and female volunteers under the resting and the motion states. For the male volunteer, the breathing frequency is 13.48 breaths per minute during the rest state and increases to 23.91 breaths per minute during the motion state. For the female volunteer, the breathing frequency is 14.12 breaths per minute during rest and rises to 24.59 breaths per minute during motion. Experimental results show that the FBG sensing unit can effectively distinguish breathing rate for the same person in different states. In addition, we employed a random forest algorithm to assess the importance of two sensors in breathing monitoring applications. The findings indicate that FBG1 outperforms FBG2 in monitoring performance, highlighting that pressure plays a positive impact in enhancing the accuracy of breathing monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Robotics Institute, School of Mechanical and Automotive Engineering, Shanghai University of Engineering Science, Shanghai 201620, China.
- Shanghai Large-Scale Component Intelligent Manufacturing Robot Technology Collaborative Innovation Center, Shanghai 201620, China.
- School of Information Engineering, Shanghai Zhongqiao Vocational and Technical University, Shanghai 201514, China.
Förderung
- National Natural Science Foundation of China under Grant
- Shanghai Local Colleges and Universities Capacity Building Plan
- National Natural Science Foundation of China
Zitieren
APA
Yan, X., Feng, Y., Xu, M., & Zhang, H. (2025). Monitoring Nasal Breathing Using an Adjustable FBG Sensing Unit. Sensors. https://doi.org/10.3390/s25134060
Vancouver
Yan X, Feng Y, Xu M, Zhang H. Monitoring Nasal Breathing Using an Adjustable FBG Sensing Unit. Sensors. 2025. doi:10.3390/s25134060
BibTeX
@article{Yan2025,
author = {Yan, Xiyan and Feng, Yan and Xu, Min and Zhang, Hua},
title = {Monitoring Nasal Breathing Using an Adjustable FBG Sensing Unit},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25134060}
}