Research on Substation Electrical Proximity Early-Warning Technology Based on the “Electric Field + Distance” Double Criterion
Sensors · 2025-06-16 · 25 (12) · 3761
DOI: 10.3390/s25123761 ↗At a glance
Journal article in Sensors, published online on 2025-06-16. Written by Jing Zhao and 8 co-authors. Institution: State Grid Chongqing Electric Power Research Institute, State Grid Chongqing Electric Power Company Ltd., Chongqing 401123, China. Cited 4 times so far (Crossref); 23 references. The full text is freely available (open access, CC BY 4.0). Funded by: State Grid Chongqing Electric Power Company, Science and Technology project "UHV Line Electrical Inspection Method and UAV Carrier Device Research and Developm…, State Grid Chongqing Electric Power Company.
Abstract (original language)
With the continuous improvement of China’s power grid, safety issues in substation operation and maintenance have become increasingly prominent. However, the existing electrical proximity early-warning devices are inadequate for the complex environments of substations, highlighting the urgent need to develop new electrical proximity early-warning technologies. Based on the safety needs of substation operators, this paper proposes an electrical proximity early-warning method that integrates ‘electric field + distance’. It combines MEMS electric field test technology with ultrasonic ranging technology and designs a double-criterion electrical proximity early-warning device. Based on the COMSOL 6.0 finite-element electric field simulation and the construction safety specification for substation equipment, a multistage electric-field early-warning threshold has been reasonably formulated. A field test conducted at a 220 kV substation demonstrates that this device can issue alerts for various electrical proximity threat levels of the circuit breaker within 0.1 s, which is faster and more accurate than existing commercial electrical proximity early-warning devices. The double-criterion early-warning system minimizes the risk of missed alarms during multi-distance measurements. Additionally, its flexible warning threshold accommodates the increasingly complex operational requirements of substations.
Subjects
Author keywords
Authors and institutions
- State Grid Chongqing Electric Power Research Institute, State Grid Chongqing Electric Power Company Ltd., Chongqing 401123, China.
- National Key Laboratory of Power Transmission and Transformation Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China.
ORCID profiles: Jing Zhao, Shengfang Li, Qianhao She, Wenyan Gan, Xian Meng, Qian Wang, Yingkai Long, Qing Yang, Jianglin Zhou
Funding
- State Grid Chongqing Electric Power Company, Science and Technology project "UHV Line Electrical Inspection Method and UAV Carrier Device Research and Developm…
- State Grid Chongqing Electric Power Company
Cite
APA
Zhao, J., Li, S., She, Q., Gan, W., Meng, X., Wang, Q., Long, Y., Yang, Q., & Zhou, J. (2025). Research on Substation Electrical Proximity Early-Warning Technology Based on the “Electric Field + Distance” Double Criterion. Sensors, 25(12), 3761. https://doi.org/10.3390/s25123761
Vancouver
Zhao J, Li S, She Q, Gan W, Meng X, Wang Q, et al. Research on Substation Electrical Proximity Early-Warning Technology Based on the “Electric Field + Distance” Double Criterion. Sensors. 2025;25(12):3761. doi:10.3390/s25123761
BibTeX
@article{Zhao2025,
author = {Zhao, Jing and Li, Shengfang and She, Qianhao and Gan, Wenyan and Meng, Xian and Wang, Qian and Long, Yingkai and Yang, Qing and Zhou, Jianglin},
title = {Research on Substation Electrical Proximity Early-Warning Technology Based on the “Electric Field + Distance” Double Criterion},
journal = {Sensors},
year = {2025},
volume = {25},
number = {12},
pages = {3761},
doi = {10.3390/s25123761}
}
EUVIMED