EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Research on Substation Electrical Proximity Early-Warning Technology Based on the “Electric Field + Distance” Double Criterion

Jing Zhao iD, Shengfang Li iD, Qianhao She iD, Wenyan Gan iD, Xian Meng iD, Qian Wang iD, Yingkai Long iD, Qing Yang iD, Jianglin Zhou iD

Sensors · 16.06.2025 · 25 (12) · 3761

DOI: 10.3390/s25123761 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 16.06.2025. Verfasst von Jing Zhao und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Grid Chongqing Electric Power Research Institute, State Grid Chongqing Electric Power Company Ltd., Chongqing 401123, China. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Chongqing Electric Power Company, Science and Technology project "UHV Line Electrical Inspection Method and UAV Carrier Device Research and Developm…, State Grid Chongqing Electric Power Company.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the continuous improvement of China’s power grid, safety issues in substation operation and maintenance have become increasingly prominent. However, the existing electrical proximity early-warning devices are inadequate for the complex environments of substations, highlighting the urgent need to develop new electrical proximity early-warning technologies. Based on the safety needs of substation operators, this paper proposes an electrical proximity early-warning method that integrates ‘electric field + distance’. It combines MEMS electric field test technology with ultrasonic ranging technology and designs a double-criterion electrical proximity early-warning device. Based on the COMSOL 6.0 finite-element electric field simulation and the construction safety specification for substation equipment, a multistage electric-field early-warning threshold has been reasonably formulated. A field test conducted at a 220 kV substation demonstrates that this device can issue alerts for various electrical proximity threat levels of the circuit breaker within 0.1 s, which is faster and more accurate than existing commercial electrical proximity early-warning devices. The double-criterion early-warning system minimizes the risk of missed alarms during multi-distance measurements. Additionally, its flexible warning threshold accommodates the increasingly complex operational requirements of substations.

Schlagwörter

Stichwörter der Autor:innen

MEMS sensordouble criterionelectrical proximity early warningultrasonic sensor

Autor:innen und Institutionen

  • State Grid Chongqing Electric Power Research Institute, State Grid Chongqing Electric Power Company Ltd., Chongqing 401123, China.
  • National Key Laboratory of Power Transmission and Transformation Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China.

ORCID-Profile: Jing Zhao, Shengfang Li, Qianhao She, Wenyan Gan, Xian Meng, Qian Wang, Yingkai Long, Qing Yang, Jianglin Zhou

Förderung

  • State Grid Chongqing Electric Power Company, Science and Technology project "UHV Line Electrical Inspection Method and UAV Carrier Device Research and Developm…
  • State Grid Chongqing Electric Power Company

Zitieren

APA

Zhao, J., Li, S., She, Q., Gan, W., Meng, X., Wang, Q., Long, Y., Yang, Q., & Zhou, J. (2025). Research on Substation Electrical Proximity Early-Warning Technology Based on the “Electric Field + Distance” Double Criterion. Sensors, 25(12), 3761. https://doi.org/10.3390/s25123761

Vancouver

Zhao J, Li S, She Q, Gan W, Meng X, Wang Q, et al. Research on Substation Electrical Proximity Early-Warning Technology Based on the “Electric Field + Distance” Double Criterion. Sensors. 2025;25(12):3761. doi:10.3390/s25123761

BibTeX
@article{Zhao2025,
  author = {Zhao, Jing and Li, Shengfang and She, Qianhao and Gan, Wenyan and Meng, Xian and Wang, Qian and Long, Yingkai and Yang, Qing and Zhou, Jianglin},
  title = {Research on Substation Electrical Proximity Early-Warning Technology Based on the “Electric Field + Distance” Double Criterion},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {12},
  pages = {3761},
  doi = {10.3390/s25123761}
}
Kostenlos starten →