Mathematical Framework for the Representation of the Travel of an Accelerometer-Based Texture Testing Device
Sensors · 2025
DOI: 10.3390/s25113273 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Harald Paulsen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Research Unit for Biomechanics and Rehabilitation Engineering, TU Wien, 1060 Vienna, Austria. Hauptthemen laut MEDLINE: Accelerometry, Models, Theoretical. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: TU Wien University Library, TU Wien.
Abstract (Originalsprache)
Recently, an accelerometer-based device (Vienna Surface Tester (VST)) has been developed for testing the surface characteristics of floors, beddings and turf grounds. The accelerometers are placed in a sphere, which will be dropped in free fall on a test surface. By observing changes in acceleration during impact, researchers can deduce various material characteristics. A down-sized version of this device (Surface Tester of Food Resilience (STFR)) has been proposed for texture testing of foods. Whereas the movement of the VST can be described by the laws of free fall, the STFR follows a constrained circular path due to its attachment to a rod and swivel. We refined the mathematical representation of the different phases of the STFR spherical probe’s trajectory (fall, impact and rebound), and we modified the mathematical models for the STFR probe to extend the measurement range.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Research Unit for Biomechanics and Rehabilitation Engineering, TU Wien, 1060 Vienna, Austria.
- Movement Science Group, University Equine Hospital, University of Veterinary Medicine, 1210 Vienna, Austria.
ORCID-Profile: Christian Peham, Johannes Peter Schramel, Margit Gföhler
Förderung
- TU Wien University Library
- TU Wien
Zitieren
APA
Paulsen, H., Peham, C., Schramel, J. P., & Gföhler, M. (2025). Mathematical Framework for the Representation of the Travel of an Accelerometer-Based Texture Testing Device. Sensors. https://doi.org/10.3390/s25113273
Vancouver
Paulsen H, Peham C, Schramel JP, Gföhler M. Mathematical Framework for the Representation of the Travel of an Accelerometer-Based Texture Testing Device. Sensors. 2025. doi:10.3390/s25113273
BibTeX
@article{Paulsen2025,
author = {Paulsen, Harald and Peham, Christian and Schramel, Johannes Peter and Gföhler, Margit},
title = {Mathematical Framework for the Representation of the Travel of an Accelerometer-Based Texture Testing Device},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25113273}
}
EUVIMED