EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Investigating the Use of Electrooculography Sensors to Detect Stress During Working Activities

Alessandra Papetti iD, Marianna Ciccarelli, Andrea Manni iD, Andrea Caroppo iD, Gabriele Rescio iD

Sensors · 2025

DOI: 10.3390/s25103015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Alessandra Papetti und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Industrial Engineering and Mathematical Sciences, Università Politecnica delle Marche, 60131 Ancona, Italy. Hauptthemen laut MEDLINE: Electrooculography, Occupational Stress. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To tackle work-related stress in the evolving landscape of Industry 5.0, organizations need to prioritize employee well-being through a comprehensive strategy. While electrocardiograms (ECGs) and electrodermal activity (EDA) are widely adopted physiological measures for monitoring work-related stress, electrooculography (EOG) remains underexplored in this context. Although less extensively studied, EOG shows significant promise for comparable applications. Furthermore, the realm of human factors and ergonomics lacks sufficient research on the integration of wearable sensors, particularly in the evaluation of human work. This article aims to bridge these gaps by examining the potential of EOG signals, captured through smart eyewear, as indicators of stress. The study involved twelve subjects in a controlled environment, engaging in four stress-inducing tasks interspersed with two-minute relaxation intervals. Emotional responses were categorized both into two classes (relaxed and stressed) and three classes (relaxed, slightly stressed, and stressed). Employing supervised machine learning (ML) algorithms—Random Forest (RF), Logistic Regression (LR), Support Vector Machine (SVM), Decision Tree (DT), and K-Nearest Neighbors (KNN)—the analysis revealed accuracy rates exceeding 80%, with RF leading at 85.8% and 82.4% for two classes and three classes, respectively. The proposed wearable system shows promise in monitoring workers’ well-being, especially during visual activities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrooculographyOccupational StressHumansAdultMaleWearable Electronic DevicesFemaleSupport Vector MachineAlgorithmsMachine LearningElectrocardiography

Stichwörter der Autor:innen

electrooculographyhuman factorsrandom forestsmart eyewearstress detectionsupervised machine learning

Autor:innen und Institutionen

  • Department of Industrial Engineering and Mathematical Sciences, Università Politecnica delle Marche, 60131 Ancona, Italy.
  • National Research Council of Italy, Institute for Microelectronics and Microsystems, Via Monteroni, c/o Campus Ecotekne, Palazzina A3, 73100 Lecce, Italy.

ORCID-Profile: Alessandra Papetti, Andrea Manni, Andrea Caroppo, Gabriele Rescio

Zitieren

APA

Papetti, A., Ciccarelli, M., Manni, A., Caroppo, A., & Rescio, G. (2025). Investigating the Use of Electrooculography Sensors to Detect Stress During Working Activities. Sensors. https://doi.org/10.3390/s25103015

Vancouver

Papetti A, Ciccarelli M, Manni A, Caroppo A, Rescio G. Investigating the Use of Electrooculography Sensors to Detect Stress During Working Activities. Sensors. 2025. doi:10.3390/s25103015

BibTeX
@article{Papetti2025,
  author = {Papetti, Alessandra and Ciccarelli, Marianna and Manni, Andrea and Caroppo, Andrea and Rescio, Gabriele},
  title = {Investigating the Use of Electrooculography Sensors to Detect Stress During Working Activities},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25103015}
}
Kostenlos starten →