EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improved SSVEP Classification Through EEG Artifact Reduction Using Auxiliary Sensors

Marcin Kołodziej iD, Andrzej Majkowski iD, Przemysław Wiszniewski iD

Sensors · 2026

DOI: 10.3390/s26030917 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Marcin Kołodziej und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Electrical Engineering, Warsaw University of Technology, Pl. Politechniki 1, 00-661 Warsaw, Poland. Hauptthemen laut MEDLINE: Electroencephalography, Evoked Potentials, Visual. Die Arbeit nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Warsaw University of Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Steady-state visual evoked potentials (SSVEPs) are one of the key paradigms used in brain–computer interface (BCI) systems. Their performance, however, is substantially degraded by EEG artifacts of muscular, motion-related, and ocular origin. This issue is particularly pronounced in individuals exhibiting increased facial muscle tension or involuntary eye movements. The aim of this study was to develop and evaluate an EEG artifact reduction method based on auxiliary channels, including central (Cz), frontal (Fp1), electrooculographic (HEOG), and muscular electrodes (neck, cheek, jaw). Signals from these channels were used to model the physical sources of interference recorded concurrently with occipital brain activity (O1, O2, Oz). EEG signal cleaning was performed using linear regression in 1-s windows, followed by frequency-domain analysis to extract features related to stimulation frequencies and SSVEP classification using SVM and CNN algorithms. The experiment involved three visual stimulation frequencies (7, 8, and 9 Hz) generated by LEDs and the recording of controlled facial and jaw-related artifacts. Experiments conducted on 12 participants demonstrated a 9% increase in classification accuracy after artifact removal. Further analysis indicated that the Cz and jaw channels contributed most significantly to effective artifact suppression. The results confirm that the use of auxiliary channels substantially improves EEG signal quality and enhances the reliability of BCI systems under real-world conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroencephalographyEvoked Potentials, VisualHumansArtifactsBrain-Computer InterfacesSignal Processing, Computer-AssistedAlgorithmsAdultMaleFemaleSupport Vector MachineElectrooculography

Stichwörter der Autor:innen

BCIEEGEMGEOGSSVEPartifact eliminationartifact reductionauxiliary sensors

Autor:innen und Institutionen

  • Faculty of Electrical Engineering, Warsaw University of Technology, Pl. Politechniki 1, 00-661 Warsaw, Poland.

ORCID-Profile: Marcin Kołodziej, Andrzej Majkowski, Przemysław Wiszniewski

Förderung

  • Warsaw University of Technology

Zitieren

APA

Kołodziej, M., Majkowski, A., & Wiszniewski, P. (2026). Improved SSVEP Classification Through EEG Artifact Reduction Using Auxiliary Sensors. Sensors. https://doi.org/10.3390/s26030917

Vancouver

Kołodziej M, Majkowski A, Wiszniewski P. Improved SSVEP Classification Through EEG Artifact Reduction Using Auxiliary Sensors. Sensors. 2026. doi:10.3390/s26030917

BibTeX
@article{Koodziej2026,
  author = {Kołodziej, Marcin and Majkowski, Andrzej and Wiszniewski, Przemysław},
  title = {Improved SSVEP Classification Through EEG Artifact Reduction Using Auxiliary Sensors},
  journal = {Sensors},
  year = {2026},
  doi = {10.3390/s26030917}
}
Kostenlos starten →