EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A LAMP Detection System Based on a Microfluidic Chip for Pyricularia grisea

Chenda Wu, Jianing Cheng, Yinchao Zhang, Ping Yao

Sensors · 2025

DOI: 10.3390/s25082511 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Chenda Wu und 3 weiteren Autor:innen. Beteiligte Einrichtung: College of Information and Electrical Engineering, Shenyang Agricultural University, Shenyang 110866, China. Hauptthemen laut MEDLINE: Lab-On-A-Chip Devices, Nucleic Acid Amplification Techniques, Ascomycota, Microfluidic Analytical Techniques. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Department of Education of Liaoning Province, China, Department of Education of Liaoning Province, China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As one of the major rice fungal diseases, blast poses a serious threat to the yield and quality of rice globally. It is caused by the pathogen Pyricularia grisea. Therefore, the development of rapid, accurate, and portable microfluidic detection system for Pyricularia grisea is important for the control of rice blast. This study presents an integrated microfluidic detection system for the rapid and sensitive detection of Pyricularia grisea using the LAMP detection method. The microfluidic detection system includes a microfluidic chip, a temperature control module, and an OpenMv camera. The micro-mixing channels with shear structures improve the mixing efficiency to about 98%. Flow-blocking valves are used to reduce reagent loss in the reaction chamber. The temperature control module is used to heat the reaction chamber, maintaining a stable temperature of 65 °C. The microfluidic chip detection chamber is used for image inspection using an OpenMv camera. The developed system can detect Pyricularia grisea in the range of 10 copies/μL–105 copies/μL within 45 min. Specificity and interference experiments were performed on Pyricularia grisea, validating the method’s good reliability. This LAMP detection system based on a microfluidic chip has strong potential in the early and effective detection of rice blast.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lab-On-A-Chip DevicesNucleic Acid Amplification TechniquesAscomycotaMicrofluidic Analytical TechniquesOryzaPlant DiseasesTemperatureMolecular Diagnostic Techniques

Stichwörter der Autor:innen

LAMPPyricularia griseaisothermal controlmicro-mixing channelsmicrofluidic chip

Autor:innen und Institutionen

  • College of Information and Electrical Engineering, Shenyang Agricultural University, Shenyang 110866, China.
  • College of Bioscience and Biotechnology, Shenyang Agricultural University, Shenyang 110866, China.
  • Liaoning Engineering Research Center for Information Technology in Agriculture, Shenyang 110866, China.

Förderung

  • The Department of Education of Liaoning Province, China
  • Department of Education of Liaoning Province, China

Zitieren

APA

Wu, C., Cheng, J., Zhang, Y., & Yao, P. (2025). A LAMP Detection System Based on a Microfluidic Chip for Pyricularia grisea. Sensors. https://doi.org/10.3390/s25082511

Vancouver

Wu C, Cheng J, Zhang Y, Yao P. A LAMP Detection System Based on a Microfluidic Chip for Pyricularia grisea. Sensors. 2025. doi:10.3390/s25082511

BibTeX
@article{Wu2025,
  author = {Wu, Chenda and Cheng, Jianing and Zhang, Yinchao and Yao, Ping},
  title = {A LAMP Detection System Based on a Microfluidic Chip for Pyricularia grisea},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25082511}
}
Kostenlos starten →