EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Integrated Droplet-Based Digital Loop-Mediated Isothermal Amplification Microfluidic Chip with Droplet Generation, Incubation, and Continuous Fluorescence Detection

Yen-Heng Lin iD, Yuan-Ting Hung, Wei Chang, Chiuan-Chian Chiou

Biosensors · 2024

DOI: 10.3390/bios14070334 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Yen-Heng Lin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Chang Gung University, Taoyuan 333, Taiwan. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, Staphylococcus aureus. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council of Taiwan, Chang Gung Memorial Hospital, National Science and Technology Council of Taiwan and the Chang Gung Memorial Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study integrated sample partition, incubation, and continuous fluorescence detection on a single microfluidic chip for droplet-based digital Loop-Mediated Isothermal Amplification (LAMP) of nucleic acids. This integration eliminated the need to transfer reactions between different platforms, avoiding sample contamination and loss. Prior to the reaction, filling the channels with an oil phase and adding a glass cover slip on top of the chip overcame the problem of bubble generation in the channels during the LAMP reaction due to heating. Additionally, using two fluorescence intensity thresholds enabled simultaneous detection and counting of positive and negative droplets within a single fluorescence detection channel. The chip can partition approximately 6000 droplets from a 5 µL sample within 10 min, with a droplet diameter of around 110 µm and a coefficient of variation (CV) value of 0.82%. Staphylococcus aureus was quantified via the proposed platform. The results demonstrated a highly accurate correlation coefficient (R = 0.9998), and the detection limit reached a concentration of 1.7 × 102 copies/µL. The entire process of the droplet digital LAMP reaction, from droplet generation to incubation to quantitative results, took a maximum of 70 min.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nucleic Acid Amplification TechniquesStaphylococcus aureusFluorescenceLab-On-A-Chip DevicesLimit of DetectionMicrofluidic Analytical TechniquesMolecular Diagnostic Techniques

Stichwörter der Autor:innen

digital LAMPdropletmicrofluidicsstaphylococcus aureus

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Chang Gung University, Taoyuan 333, Taiwan.
  • Department of Laboratory Medicine, Chang Gung Memorial Hospital, Linkou, Taoyuan 333, Taiwan.
  • Department of Electronic Engineering, Chang Gung University, Taoyuan 333, Taiwan.
  • Master and PhD Program in Biotechnology Industry, College of Medicine, Chang Gung University, Taoyuan 333, Taiwan.
  • Department of Medical Biotechnology and Laboratory Science, College of Medicine, Chang Gung University, Taoyuan 333, Taiwan.
  • Graduate Institute of Biomedical Sciences, College of Medicine, Chang Gung University, Taoyuan 333, Taiwan.

ORCID-Profile: Yen-Heng Lin

Förderung

  • National Science and Technology Council of Taiwan
  • Chang Gung Memorial Hospital
  • National Science and Technology Council of Taiwan and the Chang Gung Memorial Hospital

Zitieren

APA

Lin, Y. H., Hung, Y. T., Chang, W., & Chiou, C. C. (2024). Integrated Droplet-Based Digital Loop-Mediated Isothermal Amplification Microfluidic Chip with Droplet Generation, Incubation, and Continuous Fluorescence Detection. Biosensors. https://doi.org/10.3390/bios14070334

Vancouver

Lin YH, Hung YT, Chang W, Chiou CC. Integrated Droplet-Based Digital Loop-Mediated Isothermal Amplification Microfluidic Chip with Droplet Generation, Incubation, and Continuous Fluorescence Detection. Biosensors. 2024. doi:10.3390/bios14070334

BibTeX
@article{Lin2024,
  author = {Lin, Yen-Heng and Hung, Yuan-Ting and Chang, Wei and Chiou, Chiuan-Chian},
  title = {Integrated Droplet-Based Digital Loop-Mediated Isothermal Amplification Microfluidic Chip with Droplet Generation, Incubation, and Continuous Fluorescence Detection},
  journal = {Biosensors},
  year = {2024},
  doi = {10.3390/bios14070334}
}
Kostenlos starten →