Influence of Sampling Rate on Wearable IMU Orientation Estimation Accuracy for Human Movement Analysis
Sensors · 22.03.2025 · 25 (7) · 1976
DOI: 10.3390/s25071976 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 22.03.2025. Verfasst von Bingfei Fan und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310014, China. Hauptthemen laut MEDLINE: Wearable Electronic Devices. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Zhejiang province, Key Research and Development Program of Zhejiang province.
Abstract (Originalsprache)
Wearable inertial measurement units (IMUs) have been widely used in human movement analysis outside the laboratory. However, the IMU-based orientation estimation remains challenging, particularly in scenarios involving relatively fast movements. Increased sampling rate has the potential to improve accuracy, but it also increases power consumption and computational complexity. The relationship between sampling frequencies and accuracies remains unclear. We thus investigated the specific influence of IMU sampling frequency on orientation estimation across a spectrum of movement speeds and recommended sufficient sampling rates. Seventeen healthy subjects wore IMUs on their thigh, shank, and foot and performed walking (1.2 m/s) and running (2.2 m/s) trials on a treadmill, and a motion testbed with an IMU was used to mimic high-frequency cyclic human movements up to 3.0 Hz. Four widely used IMU sensor fusion algorithms computed orientations at 10, 25, 50, 100, 200, 400, 800, and 1600 Hz and were compared with marker-based optical motion capture (OMC) orientations to determine accuracy. Results suggest that the sufficient IMU sampling rate for walking is 100 Hz, running is 200 Hz, and high-speed cyclic movements is 400 Hz. The accelerometer sampling rate is less important than the gyroscope sampling rate. Further, accelerometer sampling rates exceeding 100 Hz even resulted in decreased accuracy because excessive orientation updates using distorted accelerations and angular velocity introduced more error than merely using angular velocity. These findings could serve as a foundation to inform wearable IMU development or selection across a spectrum of human gait movement speeds.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310014, China.
- Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310014, China.
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China.
- Department of Mechanical and Materials Engineering, Queen's University, Kingston, ON K7L 3N6, Canada.
- State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
ORCID-Profile: Bingfei Fan, Luobin Zhang, Shibo Cai, Mingyu Du, Tao Liu, Qingguo Li, Peter Shull
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Zhejiang province
- Key Research and Development Program of Zhejiang province
- National Key Research and Development Program of China
Zitieren
APA
Fan, B., Zhang, L., Cai, S., Du, M., Liu, T., Li, Q., & Shull, P. (2025). Influence of Sampling Rate on Wearable IMU Orientation Estimation Accuracy for Human Movement Analysis. Sensors, 25(7), 1976. https://doi.org/10.3390/s25071976
Vancouver
Fan B, Zhang L, Cai S, Du M, Liu T, Li Q, et al. Influence of Sampling Rate on Wearable IMU Orientation Estimation Accuracy for Human Movement Analysis. Sensors. 2025;25(7):1976. doi:10.3390/s25071976
BibTeX
@article{Fan2025,
author = {Fan, Bingfei and Zhang, Luobin and Cai, Shibo and Du, Mingyu and Liu, Tao and Li, Qingguo and Shull, Peter},
title = {Influence of Sampling Rate on Wearable IMU Orientation Estimation Accuracy for Human Movement Analysis},
journal = {Sensors},
year = {2025},
volume = {25},
number = {7},
pages = {1976},
doi = {10.3390/s25071976}
}
EUVIMED