EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Label-Free Extended Gate Field-Effect Transistor for Sensing Microcystin-LR in Freshwater Samples

Sondavid Nandanwar, Songyi Lee iD, Myeongkee Park, Hak Jun Kim iD

Sensors · 2025

DOI: 10.3390/s25051587 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Sondavid Nandanwar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Republic of Korea. Hauptthemen laut MEDLINE: Microcystins, Biosensing Techniques, Fresh Water, Transistors, Electronic. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Pukyong National University, Pukyong National University Research Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, we developed a label-free biosensor based on aptamer-modified multi-walled carbon nanotube extended gate field-effect transistor (MWCNT-EG-FET) for easy and selective detection of microcystin-LR (MC-LR), a prominent cyanotoxin associated with liver damage, bleeding, and necrosis. EG-FET had two parts: a MOSFET and an extended-gate Au/SiO2 electrode, which serves as the sensitive membrane. A custom-designed DNA oligonucleotide (5-NH2-C6-AN6) was used as MC-LR-targeting aptamer (MCTA). MWCNTs were functionalized with MCTA and then stably fixed on the sensitive membrane. The detection of MC-LR in freshwater was effectively achieved within 5 min by assessing the variations in electrical resistance that occur due to the selective interactions between MC-LR and MCTA. The detection limit and analytical sensitivity of the biosensor for MC-LR were found to be 0.134 ng/mL and 0.024 ng/mL, respectively. The sensitive membrane could be readily discarded if damaged, eliminating the need to replace the main transducer MOSFET. The developed sensor exhibits features such as straightforward preparation, swift response, potential for miniaturization, and ease of use, making it an attractive candidate for future integrated lab-on-chip systems for MC-LR detection in freshwater environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrocystinsBiosensing TechniquesFresh WaterTransistors, ElectronicMarine ToxinsAptamers, NucleotideNanotubes, CarbonLimit of DetectionElectrodesGold

Stichwörter der Autor:innen

DNA aptamerEG-FETcarbon nanotubecyanotoxinsmicrocystin

Substanzen

Microcystinscyanoginosin LRMarine ToxinsAptamers, NucleotideNanotubes, CarbonGold

Autor:innen und Institutionen

  • Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Republic of Korea.
  • Department of Chemistry, Pukyong National University, Busan 48513, Republic of Korea.

ORCID-Profile: Songyi Lee, Hak Jun Kim

Förderung

  • Pukyong National University
  • Pukyong National University Research Fund

Zitieren

APA

Nandanwar, S., Lee, S., Park, M., & Kim, H. J. (2025). Label-Free Extended Gate Field-Effect Transistor for Sensing Microcystin-LR in Freshwater Samples. Sensors. https://doi.org/10.3390/s25051587

Vancouver

Nandanwar S, Lee S, Park M, Kim HJ. Label-Free Extended Gate Field-Effect Transistor for Sensing Microcystin-LR in Freshwater Samples. Sensors. 2025. doi:10.3390/s25051587

BibTeX
@article{Nandanwar2025,
  author = {Nandanwar, Sondavid and Lee, Songyi and Park, Myeongkee and Kim, Hak Jun},
  title = {Label-Free Extended Gate Field-Effect Transistor for Sensing Microcystin-LR in Freshwater Samples},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25051587}
}
Kostenlos starten →