Development of a Multiplexed Electrochemical Aptasensor for the Detection of Cyanotoxins

Amina Rhouati, Mohammed Zourob iD

Biosensors · 2024

DOI: 10.3390/bios14060268 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Amina Rhouati und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh 11533, Saudi Arabia. Hauptthemen laut MEDLINE: Marine Toxins, Biosensing Techniques, Microcystins, Gold. Die Arbeit wurde bisher 34-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Alfaisal University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, we report a multiplexed platform for the simultaneous determination of five marine toxins. The proposed biosensor is based on a disposable electrical printed (DEP) microarray composed of eight individually addressable carbon electrodes. The electrodeposition of gold nanoparticles on the carbon surface offers high conductivity and enlarges the electroactive area. The immobilization of thiolated aptamers on the AuNP-decorated carbon electrodes provides a stable, well-orientated and organized binary self-assembled monolayer for sensitive and accurate detection. A simple electrochemical multiplexed aptasensor based on AuNPs was designed to synchronously detect multiple cyanotoxins, namely, microcystin-LR (MC-LR), Cylindrospermopsin (CYL), anatoxin-α, saxitoxin and okadaic acid (OA). The choice of the five toxins was based on their widespread presence and toxicity to aquatic ecosystems and humans. Taking advantage of the conformational change of the aptamers upon target binding, cyanotoxin detection was achieved by monitoring the resulting electron transfer increase by square-wave voltammetry. Under the optimal conditions, the linear range of the proposed aptasensor was estimated to be from 0.018 nM to 200 nM for all the toxins, except for MC-LR where detection was possible within the range of 0.073 to 150 nM. Excellent sensitivity was achieved with the limits of detection of 0.0033, 0.0045, 0.0034, 0.0053 and 0.0048 nM for MC-LR, CYL, anatoxin-α, saxitoxin and OA, respectively. Selectivity studies were performed to show the absence of cross-reactivity between the five analytes. Finally, the application of the multiplexed aptasensor to tap water samples revealed very good agreement with the calibration curves obtained in buffer. This simple and accurate multiplexed platform could open the window for the simultaneous detection of multiple pollutants in different matrices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Marine ToxinsBiosensing TechniquesMicrocystinsGoldAptamers, NucleotideElectrochemical TechniquesSaxitoxinMetal NanoparticlesCyanobacteria ToxinsBacterial ToxinsUracilTropanesAlkaloidsOkadaic AcidElectrodesLimit of Detection

Stichwörter der Autor:innen

aptasensorcyanotoxinselectrochemicalfreshwater contaminantsmultiplexed detection

Substanzen

Marine ToxinsMicrocystinsGoldAptamers, NucleotidecylindrospermopsinSaxitoxincyanoginosin LRCyanobacteria ToxinsBacterial Toxinsanatoxin a

Autor:innen und Institutionen

  • Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh 11533, Saudi Arabia.
  • Bioengineering Laboratory, Higher National School of Biotechnology, Constantine 25100, Algeria.

ORCID-Profile: Mohammed Zourob

Förderung

  • Alfaisal University

Zitieren

APA

Rhouati, A., & Zourob, M. (2024). Development of a Multiplexed Electrochemical Aptasensor for the Detection of Cyanotoxins. Biosensors. https://doi.org/10.3390/bios14060268

Vancouver

Rhouati A, Zourob M. Development of a Multiplexed Electrochemical Aptasensor for the Detection of Cyanotoxins. Biosensors. 2024. doi:10.3390/bios14060268

BibTeX
@article{Rhouati2024,
  author = {Rhouati, Amina and Zourob, Mohammed},
  title = {Development of a Multiplexed Electrochemical Aptasensor for the Detection of Cyanotoxins},
  journal = {Biosensors},
  year = {2024},
  doi = {10.3390/bios14060268}
}
Kostenlos starten →