ISFET Biosensor with Loop-Mediated Isothermal Amplification for Electronic Rapid Detection of Mycoplasma Pneumoniae
Sensors · 2025
DOI: 10.3390/s25051562 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Jie Zou und 10 weiteren Autor:innen. Beteiligte Einrichtung: Precision Medicine Translational Research Center (PMTRC), West China Hospital, Sichuan University, Chengdu 610041, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Mycoplasma pneumoniae, Nucleic Acid Amplification Techniques, Pneumonia, Mycoplasma. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the China Postdoctoral Science Foundation, the Postdoctoral Fellowship Program of CPSF, the Postdoctor Research Fund of West China Hospital, Sichuan University.
Abstract (Originalsprache)
Mycoplasma pneumoniae (MP) is the main culprit of community-acquired pneumonia. Commonly used laboratory testing methods have many shortcomings. Serological diagnosis has low sensitivity, causing false negatives, while a quantitative real-time polymerase chain reaction (qPCR) requires large equipment and professional staff. To make up for these shortcomings, we proposed a label-free, low-cost, and small-sized ion-sensitive field-effect transistor (ISFET) array based on a low-buffered loop-mediated isothermal amplification (LAMP) assay. A complementary metal oxide semiconductor (CMOS)-based ISFET array with 512 × 512 sensors was used in this system, which responds specifically to H+ with a sensitivity of 365.7 mV/pH. For on-chip amplification, a low-buffered LAMP system designed for the conserved sequences of two genes, CARDS and gyrB, was applied. The rapid release of large amounts of H+ in the low-buffered LAMP solution led to a speedy increase in electrical signals captured by the ISFET array, eliminating the need for a sophisticated temperature cycling and optical system. The on-chip results showed that the device can accurately complete MP detection with a detection limit of about 103 copies/mL (approximately 1 copy per reaction). In the final clinical validation, the detection results of eight throat swab samples using the ISFET sensors were fully consistent with the clinical laboratory diagnostic outcomes, confirming the accuracy and reliability of the ISFET sensors for use in clinical settings. And the entire process from sample lysis to result interpretation takes about 60 min. This platform has potential to be used for the point-of-care testing (POCT) of pathogen infections, providing a basis for the timely adjustment of diagnosis and treatment plans.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Precision Medicine Translational Research Center (PMTRC), West China Hospital, Sichuan University, Chengdu 610041, China.
- Department of Laboratory Medicine, Clinical Laboratory Medicine Research Center, West China Hospital, Sichuan University, Chengdu 610041, China.
- One-Chip Biotechnology Co., Ltd., Chengdu 610041, China.
Förderung
- the China Postdoctoral Science Foundation
- the Postdoctoral Fellowship Program of CPSF
- the Postdoctor Research Fund of West China Hospital, Sichuan University
- National Natural Science Foundation of China
- Postdoctoral Fellowship Program of CPSF
- China Postdoctoral Science Foundation
- Postdoctor Research Fund of West China Hospital, Sichuan University
Zitieren
APA
Zou, J., Hu, J., Shen, Y., Zhang, L., Bai, W., Wang, L., Li, J., Yan, L., Zhang, Z., Bai, H., & Hu, W. (2025). ISFET Biosensor with Loop-Mediated Isothermal Amplification for Electronic Rapid Detection of Mycoplasma Pneumoniae. Sensors. https://doi.org/10.3390/s25051562
Vancouver
Zou J, Hu J, Shen Y, Zhang L, Bai W, Wang L, et al. ISFET Biosensor with Loop-Mediated Isothermal Amplification for Electronic Rapid Detection of Mycoplasma Pneumoniae. Sensors. 2025. doi:10.3390/s25051562
BibTeX
@article{Zou2025,
author = {Zou, Jie and Hu, Jie and Shen, Yan and Zhang, Limei and Bai, Weiyi and Wang, Lei and Li, Jianlong and Yan, Lin and Zhang, Zhifeng and Bai, Hao and Hu, Wenchuang},
title = {ISFET Biosensor with Loop-Mediated Isothermal Amplification for Electronic Rapid Detection of Mycoplasma Pneumoniae},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25051562}
}
EUVIMED