An accurate and convenient method for Mycoplasma pneumoniae via one-step LAMP-CRISPR/Cas12b detection platform
Frontiers in Cellular and Infection Microbiology · 08.08.2024 · 14
DOI: 10.3389/fcimb.2024.1409078 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Cellular and Infection Microbiology, online erschienen am 08.08.2024. Verfasst von Tao Liu und 9 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Pathogenesis, Prevention, Treatment of High Incidence Diseases in Central Asian, Department of Clinical Laboratory, First Aff…. Hauptthemen laut MEDLINE: Mycoplasma pneumoniae, Nucleic Acid Amplification Techniques, Sensitivity and Specificity, Pneumonia, Mycoplasma. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Mycoplasma pneumoniae (MP) is the major cause of respiratory infections that threaten the health of children and adolescents worldwide. Therefore, an early, simple, and accurate detection approach for MP is critical to prevent outbreaks of MP-induced community-acquired pneumonia.
Methods
Here, we explored a simple and accurate method for MP identification that combines loop-mediated isothermal amplification (LAMP) with the CRISPR/Cas12b assay in a one-pot reaction.
Results
In the current study, the whole reaction was completed within 1 h at a constant temperature of 57°C. The limit of detection of this assay was 33.7 copies per reaction. The specificity of the LAMP-CRISPR/Cas12b method was 100%, without any cross-reactivity with other pathogens. Overall, 272 clinical samples were used to evaluate the clinical performance of LAMP-CRISPR/Cas12b. Compared with the gold standard results from real-time PCR, the present method provided a sensitivity of 88.11% (126/143), specificity of 100% (129/129), and consistency of 93.75% (255/272).
Discussion
Taken together, our preliminary results illustrate that the LAMP-CRISPR/Cas12b method is a simple and reliable tool for MP diagnosis that can be performed in resource-limited regions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Pathogenesis, Prevention, Treatment of High Incidence Diseases in Central Asian, Department of Clinical Laboratory, First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang Uygu…
- State Key Laboratory of Pathogenesis, Prevention, Treatment of High Incidence Diseases in Central Asian, Clinical Medical Research Institute, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjian…
Zitieren
APA
Liu, T., Liu, Q., Chen, F., Shi, Y., Maimaiti, G., Yang, Z., Zheng, S., Lu, X., Li, H., & Chen, Z. (2024). An accurate and convenient method for Mycoplasma pneumoniae via one-step LAMP-CRISPR/Cas12b detection platform. Frontiers in Cellular and Infection Microbiology, 14. https://doi.org/10.3389/fcimb.2024.1409078
Vancouver
Liu T, Liu Q, Chen F, Shi Y, Maimaiti G, Yang Z, et al. An accurate and convenient method for Mycoplasma pneumoniae via one-step LAMP-CRISPR/Cas12b detection platform. Frontiers in Cellular and Infection Microbiology. 2024;14. doi:10.3389/fcimb.2024.1409078
BibTeX
@article{Liu2024,
author = {Liu, Tao and Liu, Qing and Chen, Fuqun and Shi, Ying and Maimaiti, Guliya and Yang, Zhanhua and Zheng, Shutao and Lu, Xiaomei and Li, Hui and Chen, Zhaoyun},
title = {An accurate and convenient method for Mycoplasma pneumoniae via one-step LAMP-CRISPR/Cas12b detection platform},
journal = {Frontiers in Cellular and Infection Microbiology},
year = {2024},
volume = {14},
doi = {10.3389/fcimb.2024.1409078}
}
EUVIMED