An Optimized Maximum Second-Order Cyclostationary Blind Deconvolution and Bidirectional Long Short-Term Memory Network Model for Rolling Bearing Fault Diagnosis
Sensors · 28.02.2025 · 25 (5) · 1495
DOI: 10.3390/s25051495 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 28.02.2025. Verfasst von Jixin Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Automation, Guangdong University of Petrochemical Technology, Maoming 525000, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China, Guangdong Basic and Applied Basic Research Foundation.
Abstract (Originalsprache)
To address the challenge of extracting fault features and accurately identifying bearing fault conditions under strong noisy environments, a rolling bearing failure diagnostic technique is presented that utilizes parameter-optimized maximum second-order cyclostationary blind deconvolution (CYCBD) and bidirectional long short-term memory (BiLSTM) networks. Initially, an adaptive golden jackal optimization (GJO) algorithm is employed to refine important CYCBD parameters. Subsequently, the rolling bearing failure signals are filtered and denoised using the optimized CYCBD, producing a denoised signal. Ultimately, the noise-reduced signal is fed into the BiLSTM model to realize the classification of faults. The experimental findings demonstrate the suggested approach’s strong noise reduction performance and high diagnostic accuracy. The optimized CYCBD–BiLSTM improves the accuracy by approximately 9.89% compared with other methods when the signal-to-noise ratio (SNR) reaches −9 dB, and it can be effectively used for diagnosing rolling bearing faults under noisy backgrounds.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Automation, Guangdong University of Petrochemical Technology, Maoming 525000, China.
- School of Information and Control Engineering, Jilin Institute of Chemical Technology, Jilin 132022, China.
- School of Computer Science, Baicheng Normal University, Baicheng 137000, China.
ORCID-Profile: Mei Liu
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program of China
- Guangdong Basic and Applied Basic Research Foundation
- Guangdong Province Science and Technology Innovation Strategic Special Funding
- Maoming City Science and Technology Plan Project
- Talent Introduction Project for Guangdong University of Petrochemical Technology
Zitieren
APA
Liu, J., Deng, L., Cao, Y., Wen, C., Song, Z., Liu, M., & Cui, X. (2025). An Optimized Maximum Second-Order Cyclostationary Blind Deconvolution and Bidirectional Long Short-Term Memory Network Model for Rolling Bearing Fault Diagnosis. Sensors, 25(5), 1495. https://doi.org/10.3390/s25051495
Vancouver
Liu J, Deng L, Cao Y, Wen C, Song Z, Liu M, et al. An Optimized Maximum Second-Order Cyclostationary Blind Deconvolution and Bidirectional Long Short-Term Memory Network Model for Rolling Bearing Fault Diagnosis. Sensors. 2025;25(5):1495. doi:10.3390/s25051495
BibTeX
@article{Liu2025,
author = {Liu, Jixin and Deng, Liwei and Cao, Yue and Wen, Chenglin and Song, Zhihuan and Liu, Mei and Cui, Xiaowei},
title = {An Optimized Maximum Second-Order Cyclostationary Blind Deconvolution and Bidirectional Long Short-Term Memory Network Model for Rolling Bearing Fault Diagnosis},
journal = {Sensors},
year = {2025},
volume = {25},
number = {5},
pages = {1495},
doi = {10.3390/s25051495}
}
EUVIMED