EUVIMEDFaigh amach EUVIMED
Open access · CC BY 4.0

Smooth Moves: Comparing Log Dimensionless Jerk Metrics from Body Center of Mass Trajectory and Wearable Sensor Acceleration During Walking

Paolo Brasiliano iD, Gaspare Pavei iD, Elena Bergamini iD

Sensors · 2025

DOI: 10.3390/s25041233 ↗

At a glance

Journal article in Sensors, 2025. Written by Paolo Brasiliano and 2 co-authors. Institution: Department of Motor, Human and Health Sciences, University of Rome "Foro Italico", 00135 Roma, Italy. Major MEDLINE topics: Wearable Electronic Devices, Walking. Cited 7 times so far (Crossref); 30 references. The full text is freely available (open access, CC BY 4.0). Funded by: Italian Ministry of University and Research, ReliAble MovEment.

AchoimreSubjectsSonraí leabharliostaCiteRelated studies

Abstract (original language)

Movement smoothness is a critical metric for evaluating motor control and sensorimotor impairments, with increasing relevance in neurorehabilitation and everyday functional assessments. This study investigates the correlation between two smoothness metrics (Log Dimensionless Jerk): LDLJV, derived from body center of mass (BCoM) trajectories using a gold-standard stereophotogrammetric system, and LDLJA, calculated from acceleration data recorded via an inertial measurement unit (IMU) placed at the L1–L2 level. Ten healthy adults (six men and four women; height: 1.71 ± 0.08 m; body mass: 68.2 ± 10.2 kg; age: 34.5 ± 8.5 years) walked on a treadmill at seven different speeds, with stride-specific data analyzed to compute smoothness indices for three anatomical components (antero-posterior, medio-lateral, cranio-caudal). Concordance between the metrics was evaluated using Bland–Altman analysis, Spearman’s correlation, and the mean absolute percentage error. The results revealed weak correlations and substantial biases across all components and speeds, reflecting inherent differences between IMU- and BCoM-derived data. Correcting biases improved alignment but did not eliminate discrepancies. The findings highlight that LDLJA captures only localized trunk accelerations, whereas BCoM-derived LDLJV approximates whole-body dynamics, making direct substitution infeasible. This study emphasizes the need for careful interpretation of IMU-based metrics and contributes to refining their application in real-world gait analyses.

Subjects

MeSH terms (MEDLINE)

Wearable Electronic DevicesWalkingHumansMaleFemaleAdultAccelerationGaitBiomechanical Phenomena

Author keywords

LDLJbody center of massgait analysisinertial measurement unit (IMU)movement smoothness

Authors and institutions

  • Department of Motor, Human and Health Sciences, University of Rome "Foro Italico", 00135 Roma, Italy.
  • Department of Pathophysiology and Transplantation, University of Milan, 20133 Milano, Italy.
  • Department of Management, Information and Production Engineering, University of Bergamo, 24129 Bergamo, Italy.

ORCID profiles: Paolo Brasiliano, Gaspare Pavei, Elena Bergamini

Funding

  • Italian Ministry of University and Research
  • ReliAble MovEment

Cite

APA

Brasiliano, P., Pavei, G., & Bergamini, E. (2025). Smooth Moves: Comparing Log Dimensionless Jerk Metrics from Body Center of Mass Trajectory and Wearable Sensor Acceleration During Walking. Sensors. https://doi.org/10.3390/s25041233

Vancouver

Brasiliano P, Pavei G, Bergamini E. Smooth Moves: Comparing Log Dimensionless Jerk Metrics from Body Center of Mass Trajectory and Wearable Sensor Acceleration During Walking. Sensors. 2025. doi:10.3390/s25041233

BibTeX
@article{Brasiliano2025,
  author = {Brasiliano, Paolo and Pavei, Gaspare and Bergamini, Elena},
  title = {Smooth Moves: Comparing Log Dimensionless Jerk Metrics from Body Center of Mass Trajectory and Wearable Sensor Acceleration During Walking},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25041233}
}
Start for free →