Accurate Cardiac Duration Detection for Remote Blood Pressure Estimation Using mm-Wave Doppler Radar
Sensors · 2025
DOI: 10.3390/s25030619 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Shengze Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Science and Technology, Keio University, Yokohama 223-8522, Japan. Hauptthemen laut MEDLINE: Radar, Blood Pressure Determination, Blood Pressure, Heart. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JST ASPIRE, Japan Science and Technology Agency (JST) ASPIRE.
Abstract (Originalsprache)
This study introduces a radar-based model for estimating blood pressure (BP) in a touch-free manner. The model accurately detects cardiac activity, allowing for contactless and continuous BP monitoring. Cardiac motions are considered crucial components for estimating blood pressure. Unfortunately, because these movements are extremely subtle and can be readily obscured by breathing and background noise, accurately detecting these motions with a radar system remains challenging. Our approach to radar-based blood pressure monitoring in this research primarily focuses on cardiac feature extraction. Initially, an integrated-spectrum waveform is implemented. The method is derived from the short-time Fourier transform (STFT) and has the ability to capture and maintain minute cardiac activities. The integrated spectrum concentrates on energy changes brought about by short and high-frequency vibrations, in contrast to the pulse-wave signals used in previous works. Hence, the interference caused by respiration, random noise, and heart contractile activity can be effectively eliminated. Additionally, we present two approaches for estimating cardiac characteristics. These methods involve the application of a hidden semi-Markov model (HSMM) and a U-net model to extract features from the integrated spectrum. In our approach, the accuracy of extracted cardiac features is highlighted by the notable decreases in the root mean square error (RMSE) for the estimated interbeat intervals (IBIs), systolic time, and diastolic time, which were reduced by 87.5%, 88.7%, and 73.1%. We reached a comparable prediction accuracy even while our subject was breathing normally, despite previous studies requiring the subject to hold their breath. The diastolic BP (DBP) error of our model is 3.98±5.81 mmHg (mean absolute difference ± standard deviation), and the systolic BP (SBP) error is 6.52±7.51 mmHg.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Graduate School of Science and Technology, Keio University, Yokohama 223-8522, Japan.
- Department of Information and Computer Science, Keio University, Yokohama 223-8522, Japan.
ORCID-Profile: Shengze Wang, Mondher Bouazizi, Siyuan Yang, Tomoaki Ohtsuki
Förderung
- JST ASPIRE
- Japan Science and Technology Agency (JST) ASPIRE
Zitieren
APA
Wang, S., Bouazizi, M., Yang, S., & Ohtsuki, T. (2025). Accurate Cardiac Duration Detection for Remote Blood Pressure Estimation Using mm-Wave Doppler Radar. Sensors. https://doi.org/10.3390/s25030619
Vancouver
Wang S, Bouazizi M, Yang S, Ohtsuki T. Accurate Cardiac Duration Detection for Remote Blood Pressure Estimation Using mm-Wave Doppler Radar. Sensors. 2025. doi:10.3390/s25030619
BibTeX
@article{Wang2025,
author = {Wang, Shengze and Bouazizi, Mondher and Yang, Siyuan and Ohtsuki, Tomoaki},
title = {Accurate Cardiac Duration Detection for Remote Blood Pressure Estimation Using mm-Wave Doppler Radar},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25030619}
}
EUVIMED