A New Approach to Non-Invasive Microcirculation Monitoring: Quantifying Capillary Refill Time Using Oximetric Pulse Waves
Sensors · 2025
DOI: 10.3390/s25020330 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Sensors, 2025. Verfasst von Yuxiang Xia und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Clinical Medicine, Tsinghua University, 30 Shuangqing Road, Haidian District Beijing, Beijing 102218, China. Hauptthemen laut MEDLINE: Oximetry, Microcirculation, Microvessels, Hemodynamic Monitoring. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Toyota Interdisciplinary Project 2022, Chronic Disease Management and Emergency Response Based on Tsinghua Healthcare Intelligent System(THIS), Postdoctoral Fellowship Program of China Postdoctoral Science Foundation, Beijing Tsinghua Changgung Hospital.
Abstract (Originalsprache)
(1)
Background
To develop a novel capillary refill time measurement system and evaluate its reliability and reproducibility. (2)
Methods
Firstly, the utilization of electromagnetic pressure technology facilitates the automatic compression and instantaneous release of the finger. Secondly, the employment of pressure sensing technology and photoelectric volumetric pulse wave analysis technology enables the dynamic monitoring of blood flow in distal tissues. Thirdly, the subjects were recruited to compare the average measurement time and the number of measurements required for successful measurements. The satisfaction of doctors and patients with the instrument was investigated through the administration of questionnaires. Finally, 71 subjects were recruited and divided into two groups, A and B. Three doctors repeated the measurement of the right index fingers of the subjects. In Group A, the same measuring instrument was used, and the consistency of the measurements was evaluated using the intragroup correlation coefficient. In Group B, one doctor repeated the measurement of each subject three times using the same measuring instrument, and the reproducibility of the CRT was evaluated using the analysis of variance of the repeated measurement data. (3)
Results
The development of the capillary refill time meter was successful, with an average measurement time of 18 s and a single measurement. This study found that doctor–patient satisfaction levels were 98.3% and 100%, respectively. The intraclass correlation coefficient was 0.995 in Group A, and the p-value was greater than 0.05 in Group B. (4)
Conclusions
The non-invasive monitoring of microcirculation has been rendered both rapid and effective, thus paving the way for the further mechanization and standardization of this process. The CRT, when measured using the capillary refill time meter test machine, demonstrated consistent and reproducible results, both when assessed by different researchers and when evaluated across varying measurement sets.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Clinical Medicine, Tsinghua University, 30 Shuangqing Road, Haidian District Beijing, Beijing 102218, China.
- Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, 168 Litang Road, Changping District, Beijing 102218, China.
ORCID-Profile: Xuesong Wang
Förderung
- Toyota Interdisciplinary Project 2022, Chronic Disease Management and Emergency Response Based on Tsinghua Healthcare Intelligent System(THIS)
- Postdoctoral Fellowship Program of China Postdoctoral Science Foundation
- Beijing Tsinghua Changgung Hospital
Zitieren
APA
Xia, Y., Wang, X., Guo, Z., Wang, X., & Wang, Z. (2025). A New Approach to Non-Invasive Microcirculation Monitoring: Quantifying Capillary Refill Time Using Oximetric Pulse Waves. Sensors. https://doi.org/10.3390/s25020330
Vancouver
Xia Y, Wang X, Guo Z, Wang X, Wang Z. A New Approach to Non-Invasive Microcirculation Monitoring: Quantifying Capillary Refill Time Using Oximetric Pulse Waves. Sensors. 2025. doi:10.3390/s25020330
BibTeX
@article{Xia2025,
author = {Xia, Yuxiang and Wang, Xinrui and Guo, Zhe and Wang, Xuesong and Wang, Zhong},
title = {A New Approach to Non-Invasive Microcirculation Monitoring: Quantifying Capillary Refill Time Using Oximetric Pulse Waves},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25020330}
}
EUVIMED