EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Reliability of a Low-Cost Inertial Measurement Unit (IMU) to Measure Punch and Kick Velocity

Lukas Pezenka, Klaus Wirth

Sensors · 2025

DOI: 10.3390/s25020307 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Lukas Pezenka und 1 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Sport Science, University of Applied Sciences Wiener Neustadt, 2700 Wiener Neustadt, Austria. Hauptthemen laut MEDLINE: Accelerometry. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Striking velocity is a key performance indicator in striking-based combat sports, such as boxing, Karate, and Taekwondo. This study aims to develop a low-cost, accelerometer-based system to measure kick and punch velocities in combat athletes. Utilizing a low-cost mobile phone in conjunction with the PhyPhox app, acceleration data was collected and analyzed using a custom algorithm. This involved strike segmentation and numerical integration to determine velocity. The system demonstrated moderate reliability (intraclass correlation coefficient (ICC) 3,1 = 0.746 to 0.786, standard error of measurement (SEM) = 0.488 to 0.921 m/s), comparable to commercially available systems. Biological and technical variations, as well as test standardization issues, were acknowledged as factors influencing reliability. Despite a relatively low sampling frequency, the hardware and software showed potential for reliable measurement. The study highlights the importance of considering within-subject variability, hardware limitations, and the impact of noise in software algorithms. Average strike velocities exhibited higher reliability than peak velocities, making them a practical choice for performance tracking, although they may underestimate true peak performance. Future research should validate the system against gold-standard methods and determine the optimal sampling frequency to enhance measurement accuracy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AccelerometryHumansAlgorithmsReproducibility of ResultsAccelerationMaleAdultAthletic PerformanceMartial ArtsSoftware

Stichwörter der Autor:innen

accelerometrycombat sportskinematicsreliability

Autor:innen und Institutionen

  • Institute of Sport Science, University of Applied Sciences Wiener Neustadt, 2700 Wiener Neustadt, Austria.

Zitieren

APA

Pezenka, L., & Wirth, K. (2025). Reliability of a Low-Cost Inertial Measurement Unit (IMU) to Measure Punch and Kick Velocity. Sensors. https://doi.org/10.3390/s25020307

Vancouver

Pezenka L, Wirth K. Reliability of a Low-Cost Inertial Measurement Unit (IMU) to Measure Punch and Kick Velocity. Sensors. 2025. doi:10.3390/s25020307

BibTeX
@article{Pezenka2025,
  author = {Pezenka, Lukas and Wirth, Klaus},
  title = {Reliability of a Low-Cost Inertial Measurement Unit (IMU) to Measure Punch and Kick Velocity},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25020307}
}
Kostenlos starten →