EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Concurrent validity and between-device reliability of the Catapult Vector S8 GNSS device

Susanne Ellens iD, Codey Moran, Matthew C Varley

PLOS One · 2025

DOI: 10.1371/journal.pone.0333792 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Susanne Ellens und 2 weiteren Autor:innen. Beteiligte Einrichtung: Sport, Performance, and Nutrition Research Group, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, Australia. Hauptthemen laut MEDLINE: Running, Athletic Performance, Accelerometry. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study assessed the concurrent validity and between-device reliability of the Catapult Vector S8 GNSS device for measuring distance, speed, acceleration and banded distance metrics. Twelve male sub-elite team sport athletes completed a testing protocol consisting of linear sprints, change of direction drills and a modified small-sided game. Validity was evaluated against criterion reference systems, a VICON motion capture system for most trials and a Stalker ATS radar for 50 m sprints, evaluated using root mean square error (RMSE) and mean bias. Between-device reliability was assessed using interclass correlation coefficients (ICC) and typical error (TE%). The Vector S8 demonstrated good validity with minimal errors for instantaneous distance (RMSE: 0.03 ± 0.01 m), speed (RMSE: 0.14 ± 0.05 m·s −1 ) and acceleration (RMSE: 0.29 ± 0.14 m·s −2 ). No overall bias was detected for instantaneous distance and speed, and the bias for acceleration (−0.016) was minimal. Accumulated distance showed a small underestimation across trials (mean bias −1.42%), with consistently low RMSE values (0.26–3.06 m), indicating high measurement precision. The 50 m sprint results showed similar validity, with minimal RMSE for instantaneous speed (0.14 ± 0.15 m·s −1 ) and acceleration (0.22 ± 0.22 m·s −2 ). Between device reliability demonstrated excellent agreement across all measured variables (ICC ≥ 0.95) with good precision (TE as CV < 3.13%). No significant systematic bias was observed between devices for any variable (p > 0.05). This is the first study to validate the Catapult Vector S8 GNSS device, demonstrating that it is valid and reliable for measuring distance, speed and acceleration during sport-specific movements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RunningAthletic PerformanceAccelerometryHumansMaleReproducibility of ResultsAccelerationYoung AdultAthletes

Autor:innen und Institutionen

  • Sport, Performance, and Nutrition Research Group, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, Australia.
  • Catapult, Melbourne, Australia.

ORCID-Profile: Susanne Ellens

Zitieren

APA

Ellens, S., Moran, C., & Varley, M. C. (2025). Concurrent validity and between-device reliability of the Catapult Vector S8 GNSS device. PLOS One. https://doi.org/10.1371/journal.pone.0333792

Vancouver

Ellens S, Moran C, Varley MC. Concurrent validity and between-device reliability of the Catapult Vector S8 GNSS device. PLOS One. 2025. doi:10.1371/journal.pone.0333792

BibTeX
@article{Ellens2025,
  author = {Ellens, Susanne and Moran, Codey and Varley, Matthew C},
  title = {Concurrent validity and between-device reliability of the Catapult Vector S8 GNSS device},
  journal = {PLOS One},
  year = {2025},
  doi = {10.1371/journal.pone.0333792}
}
Kostenlos starten →