EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-Intrusive Monitoring of Vital Signs in the Lower Limbs Using Optical Sensors

Joana Simões iD, Regina Oliveira iD, Florinda M Costa iD, António Teixeira iD, Cátia Leitão iD, Pedro Correia iD, Ana Luísa M Silva iD

Sensors · 2025

DOI: 10.3390/s25020305 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Joana Simões und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), Department of Physics, University of Aveiro, 3810-193 Aveiro, Portugal. Hauptthemen laut MEDLINE: Photoplethysmography, Lower Extremity, Vital Signs. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: PRR - Plano de Recuperação e 253 Resiliência under the Next Generation EU from the European Union, FCT, PRR – Plano de Recuperação e Resiliência under the Next Generation EU from the European Union.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Invisible health monitoring is currently a topic of global interest within the scientific community. Sensorization of everyday objects can provide valuable health information without requiring any changes in people’s routines. In this work, a feasibility study of photoplethysmography (PPG) acquisition in the lower limbs for continuous and real-time monitoring of the vital signs, including heart rate (HR) and respiratory rate (RR), is presented. The proposed system uses two MAX30102 sensors to obtain PPG signals from the back of the thigh. As proof of concept, tests were conducted in 17 volunteers (age group between 22 and 40 years old, twelve females and five males), and the results were compared to those of reference sensors. A Pearson correlation coefficient of r = 0.92 and r = 0.77 and a mean difference of 1.2 bpm and 0.9 rpm for HR and RR, respectively, were obtained between the developed system and reference. System accuracies of 95.9% for HR and 91.3% for RR were achieved, showing the system viability for vital sign monitoring of the lower limbs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotoplethysmographyLower ExtremityVital SignsHumansMaleFemaleAdultMonitoring, PhysiologicHeart RateRespiratory RateYoung Adult

Stichwörter der Autor:innen

heart rateinvisible health monitoringlower limbsoptical sensorphotoplethysmographyrespiratory rate

Autor:innen und Institutionen

  • Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), Department of Physics, University of Aveiro, 3810-193 Aveiro, Portugal.
  • Institute of Electronics and Informatics Engineering of Aveiro (IEETA), Department of Electronics Telecommunications & Informatics, University of Aveiro, 3810-193 Aveiro, Portugal.

ORCID-Profile: Joana Simões, Regina Oliveira, Florinda M Costa, António Teixeira, Cátia Leitão, Pedro Correia, Ana Luísa M Silva

Förderung

  • PRR - Plano de Recuperação e 253 Resiliência under the Next Generation EU from the European Union
  • FCT
  • PRR – Plano de Recuperação e Resiliência under the Next Generation EU from the European Union
  • National funds through the FCT and MEC of Portugal
  • CEEC

Zitieren

APA

Simões, J., Oliveira, R., Costa, F. M., Teixeira, A., Leitão, C., Correia, P., & Silva, A. L. M. (2025). Non-Intrusive Monitoring of Vital Signs in the Lower Limbs Using Optical Sensors. Sensors. https://doi.org/10.3390/s25020305

Vancouver

Simões J, Oliveira R, Costa FM, Teixeira A, Leitão C, Correia P, et al. Non-Intrusive Monitoring of Vital Signs in the Lower Limbs Using Optical Sensors. Sensors. 2025. doi:10.3390/s25020305

BibTeX
@article{Simes2025,
  author = {Simões, Joana and Oliveira, Regina and Costa, Florinda M and Teixeira, António and Leitão, Cátia and Correia, Pedro and Silva, Ana Luísa M},
  title = {Non-Intrusive Monitoring of Vital Signs in the Lower Limbs Using Optical Sensors},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25020305}
}
Kostenlos starten →