EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Background Light Suppression for Multispectral Imaging in Surgical Settings

Moritz Gerlich iD, Andreas Schmid, Thomas Greiner iD, Stefan Kray iD

Sensors · 2024

DOI: 10.3390/s25010141 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Moritz Gerlich und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Smart Systems and Services, Pforzheim University, 75175 Pforzheim, Germany. Hauptthemen laut MEDLINE: Surgery, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Carl-Zeiss-Stiftung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multispectral imaging (MSI) enables non-invasive tissue differentiation based on spectral characteristics and has shown great potential as a tool for surgical guidance. However, adapting MSI to open surgeries is challenging. Systems that rely on light sources present in the operating room experience limitations due to frequent lighting changes, which distort the spectral data and require countermeasures such as disruptive recalibrations. On the other hand, MSI systems that rely on dedicated lighting require external light sources, such as surgical lights, to be turned off during open surgery settings. This disrupts the surgical workflow and extends operation times. To this end, we present an approach that addresses these issues by combining active illumination with smart background suppression. By alternately capturing images with and without a modulated light source at a desired wavelength, we isolate the target signal, enabling artifact-free spectral scanning. We demonstrate the performance of our approach using a smart pixel camera, emphasizing its signal-to-noise ratio (SNR) advantage over a conventional high-speed camera. Our results show that accurate reflectance measurements can be achieved in clinical settings with high background illumination. Medical application is demonstrated through the estimation of blood oxygenation, and its suitability for open surgeries is discussed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgery, Computer-AssistedHumansSignal-To-Noise RatioLightLightingImage Processing, Computer-AssistedOxygen

Stichwörter der Autor:innen

background suppressionmultispectral imagingopen surgeriesspectral scanning

Substanzen

Oxygen

Autor:innen und Institutionen

  • Institute of Smart Systems and Services, Pforzheim University, 75175 Pforzheim, Germany.

ORCID-Profile: Moritz Gerlich, Thomas Greiner, Stefan Kray

Förderung

  • Carl-Zeiss-Stiftung

Zitieren

APA

Gerlich, M., Schmid, A., Greiner, T., & Kray, S. (2024). Background Light Suppression for Multispectral Imaging in Surgical Settings. Sensors. https://doi.org/10.3390/s25010141

Vancouver

Gerlich M, Schmid A, Greiner T, Kray S. Background Light Suppression for Multispectral Imaging in Surgical Settings. Sensors. 2024. doi:10.3390/s25010141

BibTeX
@article{Gerlich2024,
  author = {Gerlich, Moritz and Schmid, Andreas and Greiner, Thomas and Kray, Stefan},
  title = {Background Light Suppression for Multispectral Imaging in Surgical Settings},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s25010141}
}
Kostenlos starten →