EUVIMEDEUVIMED entdecken
Crossref

Influence of ambient light color temperature and illuminance on the accuracy of 3-dimensional patient representation using different facial scanning technologies: A clinical study

Panagiotis Ntovas, Ourania Ladia, Abdul B Barmak, Vincent Fehmer, Irena Sailer, Marta Revilla-León

The Journal of Prosthetic Dentistry · 2026

DOI: 10.1016/j.prosdent.2026.06.004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Panagiotis Ntovas und 5 weiteren Autor:innen. Beteiligte Einrichtung: Scientific Affiliate, Department of Operative Dentistry, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece; Adjunct…. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Face, Lighting. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Face scans combined with intraoral scans enable the representation of 3-dimensional patient models, facilitating virtual dentofacial analysis. However, the influence of ambient light on facial scanning for virtual patient representations remain unclear. PURPOSE: The purpose of this clinical study was to investigate the influence of different ambient light color temperatures and illuminance of facial scanning procedures on the accuracy of virtual patient models. MATERIAL AND METHODS: Ten participants were scanned using 2 professional (MetiSmile, Rayface 200) and 3 smartphone based (Heges, Qlone, EM3D) face scanners. For each face scanner, each participant was scanned 12 times under varying ambient light conditions. Three color temperatures (3300, 5500, 8000 K) and 3 levels of illuminance (500, 5000, 10 000 lx) were investigated. Intraoral scans were obtained, followed by facial scans. Before facial scanning, 4 landmarks were placed on the participant's face. Each facial model was superimposed onto the intraoral scan to create a virtual patient representation. Digital integration was performed following both a tooth based and an extraoral scan body based workflow. Using digital calipers, 20 linear distances between predefined facial landmarks and 5 reference points on the teeth were measured manually and served as control data. The same distances were measured virtually using a metrology software program. Statistical analysis was performed using 2-way ANOVA for pairwise comparisons (α=.05). RESULTS: A 500 lx illuminance facial scanning method led in significantly worse trueness and precision for virtual patient representations when professional face scanners were used, compared to 5000 lx and 10 000 lx, for both tooth- and extraoral scan body-based integration. For smartphone based face scanners, 500 lx led to a significant reduction in accuracy only when extraoral scan body-based integration was performed. Deviations from 5500 K were associated with a significant decrease in trueness, with the effect varying for each face scanner and digital integration method investigated. CONCLUSIONS: To maximize accuracy of virtual patient representation, clinicians should consider the effect of ambient lighting conditions, including illuminance level and color temperature, in conjunction with the type of facial scanner and digital integration method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalFaceLightingHumansColorFemaleMaleAdultSmartphoneImage Processing, Computer-AssistedAnatomic LandmarksTemperatureUser-Computer InterfaceLight

Autor:innen und Institutionen

  • Scientific Affiliate, Department of Operative Dentistry, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece; Adjunct Faculty, Department of Prosthodontics, School of Dental Medicine, Tuf…
  • Scientific Affiliate, Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece.
  • Associate Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, N.Y.
  • Master Dental Technician, Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.
  • Professor, Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.
  • Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director of Research and Digital Dentistry, Kois Ce…

Zitieren

APA

Ntovas, P., Ladia, O., Barmak, A. B., Fehmer, V., Sailer, I., & Revilla-León, M. (2026). Influence of ambient light color temperature and illuminance on the accuracy of 3-dimensional patient representation using different facial scanning technologies: A clinical study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2026.06.004

Vancouver

Ntovas P, Ladia O, Barmak AB, Fehmer V, Sailer I, Revilla-León M. Influence of ambient light color temperature and illuminance on the accuracy of 3-dimensional patient representation using different facial scanning technologies: A clinical study. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2026.06.004

BibTeX
@article{Ntovas2026,
  author = {Ntovas, Panagiotis and Ladia, Ourania and Barmak, Abdul B and Fehmer, Vincent and Sailer, Irena and Revilla-León, Marta},
  title = {Influence of ambient light color temperature and illuminance on the accuracy of 3-dimensional patient representation using different facial scanning technologies: A clinical study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  doi = {10.1016/j.prosdent.2026.06.004}
}
Kostenlos starten →