Kinematical and Physiological Responses of Overground Running Gait Pattern at Different Intensities
Sensors · 2024
DOI: 10.3390/s24237526 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Ana Sofia Monteiro und 5 weiteren Autor:innen. Beteiligte Einrichtung: Centre of Research, Education, Innovation and Intervention in Sport and Porto Biomechanics Laboratory, Faculty of Sport, University of Porto, 4200-45…. Hauptthemen laut MEDLINE: Running, Gait. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e Tecnologia, EU, FCT.
Abstract (Originalsprache)
Runners achieve forward locomotion through diverse techniques. However, understanding the behavior of the involved kinematical variables remains incomplete, particularly when running overground and along an intensity spectrum. We aimed to characterize the biomechanical and physiological adaptations while running at low, moderate, heavy and severe intensities. Ten middle- and long-distance runners completed an incremental intermittent protocol of 800 m steps until exhaustion (1 km·h−1 velocity increments and 30 s intervals) on an outdoor track field. Biomechanical data were captured using two high-resolution video cameras, and linear and angular kinematic variables were analyzed. With the intensity rise, a decrease in stride, step and contact times ([0.70–0.65], [0.35–0.33] and [0.42–0.37] s) and an increase in stride length and frequency and flight time ([3.13–3.52] m, [1.43–1.52] Hz and [0.28–0.29] s; p < 0.05) were observed, together with an increase in oxygen uptake and blood lactate concentrations ([54.7–67.6] mL∙kg−1∙min−1 and [3.1–10.2] mmol∙L−1). A more flexed hip at initial contact and toe-off (152.02–149.36] and [165.70–163.64]) and knee at initial contact ([162.64–159.57]; p < 0.05) were also observed. A consistent gait pattern along each protocol step was exhibited, with minor changes without practical significance. Runners are constantly adapting their gait pattern, reflected in both biomechanical and physiological responses, both of which should be considered for better characterization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Centre of Research, Education, Innovation and Intervention in Sport and Porto Biomechanics Laboratory, Faculty of Sport, University of Porto, 4200-450 Porto, Portugal.
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, 27100 Pavia, Italy.
ORCID-Profile: Ana Sofia Monteiro, Filipa Cardoso, Cosme F Buzzachera, João Paulo Vilas-Boas, Ricardo J Fernandes
Förderung
- Fundação para a Ciência e Tecnologia
- EU
- FCT
Zitieren
APA
Monteiro, A. S., Galano, J. P., Cardoso, F., Buzzachera, C. F., Vilas-Boas, J. P., & Fernandes, R. J. (2024). Kinematical and Physiological Responses of Overground Running Gait Pattern at Different Intensities. Sensors. https://doi.org/10.3390/s24237526
Vancouver
Monteiro AS, Galano JP, Cardoso F, Buzzachera CF, Vilas-Boas JP, Fernandes RJ. Kinematical and Physiological Responses of Overground Running Gait Pattern at Different Intensities. Sensors. 2024. doi:10.3390/s24237526
BibTeX
@article{Monteiro2024,
author = {Monteiro, Ana Sofia and Galano, João Paulo and Cardoso, Filipa and Buzzachera, Cosme F and Vilas-Boas, João Paulo and Fernandes, Ricardo J},
title = {Kinematical and Physiological Responses of Overground Running Gait Pattern at Different Intensities},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24237526}
}
EUVIMED