Determining the minimum number of steps required for reliable kinetic, kinematic, gait variability, and V̇O2 parameters in outdoor running
British Medical Bulletin · 02.01.2026 · 157 (1)
DOI: 10.1093/bmb/ldaf025 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Medical Bulletin, online erschienen am 12.01.2026. Verfasst von Johnny Padulo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Sciences for Health, Università degli Studi di Milano, 20133 Milan, Italy. Hauptthemen laut MEDLINE: Running, Oxygen Consumption, Gait Analysis, Gait. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Università degli Studi di Milano.
Abstract (Originalsprache)
Introduction Outdoor running gait analysis using wearable sensors requires establishing minimum step requirements for reliable parameter measurement. Sources of data Fourteen trained runners completed 10-minute trials at critical speed. RunScribe™ captured kinetic/kinematic data at 500 Hz. Convergence analysis determined minimum steps when cumulative means stabilized within ±2% for ≥10 consecutive steps. Areas of agreement Most parameters achieved excellent reliability (ICC > 0.900). Metabolic parameters (V̇O₂: 108 ± 32 steps) and step rate (124 ± 36 steps) converged fastest, while kinematic variables required moderate sampling (stride length: 152 ± 48 steps; contact time: 198 ± 52 steps). Areas of controversy Complex biomechanical metrics showed substantial variability: leg stiffness (kleg: 342 ± 78 steps; kvert: 298 ± 71 steps) and gait variability (246 ± 12 steps) required substantially more data, challenging brief field assessment feasibility. Growing points This study establishes parameter-specific sampling protocols for outdoor gait analysis, demonstrating that different measurement domains require tailored data collection strategies to optimize ecological validity. Areas timely for developing research Future research should examine how speed, terrain, and environmental conditions affect sampling requirements. Adaptive protocols and machine learning approaches offer promising opportunities for optimizing data collection efficiency.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, 20133 Milan, Italy.
- Unidad Académica de Biofísica, Facultad de Medicina, Universidad de la República, 11800 Montevideo, Uruguay.
- Human Locomotion Laboratory (LocoLab), Department of Public Health, Experimental and Forensic Medicine, University of Pavia, 27100 Pavia, Italy.
ORCID-Profile: Johnny Padulo, Raffaele Scurati, Fabio Esposito, Leonardo Alexandre Peyré-Tartaruga
Förderung
- Università degli Studi di Milano
Zitieren
APA
Padulo, J., Scurati, R., Baldo, S., Esposito, F., & Peyré-Tartaruga, L. A. (2026). Determining the minimum number of steps required for reliable kinetic, kinematic, gait variability, and V̇O2 parameters in outdoor running. British Medical Bulletin, 157(1). https://doi.org/10.1093/bmb/ldaf025
Vancouver
Padulo J, Scurati R, Baldo S, Esposito F, Peyré-Tartaruga LA. Determining the minimum number of steps required for reliable kinetic, kinematic, gait variability, and V̇O2 parameters in outdoor running. British Medical Bulletin. 2026;157(1). doi:10.1093/bmb/ldaf025
BibTeX
@article{Padulo2026,
author = {Padulo, Johnny and Scurati, Raffaele and Baldo, Simone and Esposito, Fabio and Peyré-Tartaruga, Leonardo Alexandre},
title = {Determining the minimum number of steps required for reliable kinetic, kinematic, gait variability, and V̇O2 parameters in outdoor running},
journal = {British Medical Bulletin},
year = {2026},
volume = {157},
number = {1},
doi = {10.1093/bmb/ldaf025}
}
EUVIMED