EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Microdetection of Nucleocapsid Proteins via Terahertz Chemical Microscope Using Aptamers

Xue Ding, Mana Murakami, Jin Wang iD, Hirofumi Inoue, Toshihiko Kiwa iD

Sensors · 2024

DOI: 10.3390/s24227382 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Xue Ding und 4 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama 700-8530, Japan. Hauptthemen laut MEDLINE: SARS-CoV-2, COVID-19, Aptamers, Nucleotide. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, JST SPRING, Japan, JSPS KAKENHI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the detection of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), several methods have been employed, including the detection of viral ribonucleic acid (RNA), nucleocapsid (N) proteins, spike proteins, and antibodies. RNA detection, primarily through polymerase chain reaction tests, targets the viral genetic material, whereas antigen tests detect N and spike proteins to identify active infections. In addition, antibody tests are performed to measure the immune response, indicating previous exposure or vaccination. Here, we used the developed terahertz chemical microscope (TCM) to detect different concentrations of N protein in solution by immobilizing aptamers on a semiconductor substrate (sensing plate) and demonstrated that the terahertz amplitude varies as the concentration of N proteins increases, exhibiting a highly linear relationship with a coefficient of determination (R2 = 0.9881), indicating that a quantitative measurement of N proteins is achieved. By optimizing the reaction conditions, we confirmed that the amplitude of the terahertz wave was independent of the solution volume. Consequently, trace amounts (0.5 μL) of the N protein were successfully detected, and the detection process only took 10 min. Therefore, this study is expected to develop a rapid and sensitive method for the detection and observation of the SARS-CoV-2 virus at a microdetection level. It is anticipated that this research will significantly contribute to reducing the spread of novel infectious diseases in the future.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SARS-CoV-2COVID-19Aptamers, NucleotideHumansCoronavirus Nucleocapsid ProteinsBiosensing TechniquesMicroscopyNucleocapsid ProteinsRNA, ViralPhosphoproteins

Stichwörter der Autor:innen

N proteinaptamersmicrodetectionterahertz chemical microscope

Substanzen

Aptamers, NucleotideCoronavirus Nucleocapsid Proteinsnucleocapsid phosphoprotein, SARS-CoV-2Nucleocapsid ProteinsRNA, ViralPhosphoproteins

Autor:innen und Institutionen

  • Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama 700-8530, Japan.
  • Graduate School of Medicine Dentistry and Pharmaceutical Sciences, Okayama University Hospital, Okayama 700-8558, Japan.

ORCID-Profile: Jin Wang, Toshihiko Kiwa

Förderung

  • Japan Society for the Promotion of Science
  • JST SPRING, Japan
  • JSPS KAKENHI

Zitieren

APA

Ding, X., Murakami, M., Wang, J., Inoue, H., & Kiwa, T. (2024). Microdetection of Nucleocapsid Proteins via Terahertz Chemical Microscope Using Aptamers. Sensors. https://doi.org/10.3390/s24227382

Vancouver

Ding X, Murakami M, Wang J, Inoue H, Kiwa T. Microdetection of Nucleocapsid Proteins via Terahertz Chemical Microscope Using Aptamers. Sensors. 2024. doi:10.3390/s24227382

BibTeX
@article{Ding2024,
  author = {Ding, Xue and Murakami, Mana and Wang, Jin and Inoue, Hirofumi and Kiwa, Toshihiko},
  title = {Microdetection of Nucleocapsid Proteins via Terahertz Chemical Microscope Using Aptamers},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24227382}
}
Kostenlos starten →