EUVIMEDEUVIMED entdecken
Crossref

An electrochemical microsensor of the SARS-CoV-2 nucleocapsid protein based on a surface-imprinted acupuncture needle

Yan Liu, Xue Kong, Yi Zhang, Xiumei Zhou, Zheng-Zhi Yin

The Analyst · 2025

DOI: 10.1039/d4an01497a ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Analyst, 2025. Verfasst von Yan Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310018, China. zhouxiumei824@163.com. Hauptthemen laut MEDLINE: Electrochemical Techniques, Biosensing Techniques, Coronavirus Nucleocapsid Proteins, Needles. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: China Postdoctoral Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A novel electrochemical microsensor was constructed on a traditional acupuncture needle (AN) and used to monitor a biomarker of the SARS-CoV-2-N protein.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrochemical TechniquesBiosensing TechniquesCoronavirus Nucleocapsid ProteinsNeedlesNucleocapsid ProteinsPhosphoproteinsSARS-CoV-2HumansCOVID-19GoldBoronic AcidsMetal NanoparticlesSulfhydryl CompoundsLimit of Detection

Substanzen

Coronavirus Nucleocapsid Proteinsnucleocapsid phosphoprotein, SARS-CoV-2GoldBoronic Acids4-mercaptophenylboronic acidNucleocapsid ProteinsSulfhydryl CompoundsPhosphoproteins

Autor:innen und Institutionen

  • College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310018, China. zhouxiumei824@163.com.
  • Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological and Chemical Engineering, Jiaxing University, Jiaxing 314001, China.

Förderung

  • China Postdoctoral Science Foundation

Zitieren

APA

Liu, Y., Kong, X., Zhang, Y., Zhou, X., & Yin, Z. Z. (2025). An electrochemical microsensor of the SARS-CoV-2 nucleocapsid protein based on a surface-imprinted acupuncture needle. The Analyst. https://doi.org/10.1039/d4an01497a

Vancouver

Liu Y, Kong X, Zhang Y, Zhou X, Yin ZZ. An electrochemical microsensor of the SARS-CoV-2 nucleocapsid protein based on a surface-imprinted acupuncture needle. The Analyst. 2025. doi:10.1039/d4an01497a

BibTeX
@article{Liu2025,
  author = {Liu, Yan and Kong, Xue and Zhang, Yi and Zhou, Xiumei and Yin, Zheng-Zhi},
  title = {An electrochemical microsensor of the SARS-CoV-2 nucleocapsid protein based on a surface-imprinted acupuncture needle},
  journal = {The Analyst},
  year = {2025},
  doi = {10.1039/d4an01497a}
}
Kostenlos starten →