Demonstration of a Validated Direct Current Wearable Device for Monitoring Sweat Rate in Sports
Sensors · 2024
DOI: 10.3390/s24227243 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Xing Xuan und 4 weiteren Autor:innen. Beteiligte Einrichtung: UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Sweat. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Council (ERC) under the European Union's Horizon 2020 Research and Innovation Programme, Swedish Research Council, UCAM.
Abstract (Originalsprache)
Sweat rate magnitude is a desired outcome for any wearable sensing patch dedicated to sweat analysis. Indeed, sweat rate values can be used two-fold: self-diagnosis of dehydration and correction/normalization of other physiological metrics, such as Borg scale, VO2, and different chemical species concentrations. Herein, a reliable sweat rate belt device for sweat rate monitoring was developed. The device measures sweat rates in the range from 1.0 to 5.0 µL min−1 (2 to 10 µL min−1 cm−2), which covers typical values for humans. The working mechanism is based on a new direct current (DC) step protocol activating a series of differential resistance measurements (spatially separated by 800 µm) that is gradually initiated by the action of sweat, which flows along a customized microfluidic track (~600 µm in width, 10 mm in length, and 235 µm in thickness). The device has a volumetric capacity of ~16 µL and an acquisition frequency between 0.010 and 0.043 Hz within the measured sweat rate range. Importantly, instead of using a typical and rather complex AC signal interrogation and acquisition, we put forward the DC approach, offering several benefits, such as simplified circuit design for easier fabrication and lower costs, as well as reduced power consumption and suitability for wearable applications. For the validation, either the commercial sweat collector (colorimetric) or the developed device was performed. In five on-body tests, an acceptable variation of ca. 10% was obtained. Overall, this study demonstrates the potential of the DC-based device for the monitoring of sweat rate and also its potential for implementation in any wearable sweat platform.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain.
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden.
ORCID-Profile: Daniel Rojas, Isabel Maria Diaz Lozano, Maria Cuartero, Gastón A Crespo
Förderung
- European Research Council (ERC) under the European Union's Horizon 2020 Research and Innovation Programme
- Swedish Research Council
- UCAM
- European Research Council (ERC) under the European Union’s Horizon 2020 Research and Innovation Programme
Zitieren
APA
Xuan, X., Rojas, D., Lozano, I. M. D., Cuartero, M., & Crespo, G. A. (2024). Demonstration of a Validated Direct Current Wearable Device for Monitoring Sweat Rate in Sports. Sensors. https://doi.org/10.3390/s24227243
Vancouver
Xuan X, Rojas D, Lozano IMD, Cuartero M, Crespo GA. Demonstration of a Validated Direct Current Wearable Device for Monitoring Sweat Rate in Sports. Sensors. 2024. doi:10.3390/s24227243
BibTeX
@article{Xuan2024,
author = {Xuan, Xing and Rojas, Daniel and Lozano, Isabel Maria Diaz and Cuartero, Maria and Crespo, Gastón A},
title = {Demonstration of a Validated Direct Current Wearable Device for Monitoring Sweat Rate in Sports},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24227243}
}
EUVIMED