EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Estimation of the Number of Active Sweat Glands Through Discrete Sweat Sensing

Jelte R Haakma iD, Elisabetta Peri iD, Simona Turco iD, Eduard Pelssers, Jaap M J den Toonder iD, Massimo Mischi iD

Sensors · 2024

DOI: 10.3390/s24227187 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Jelte R Haakma und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands. Hauptthemen laut MEDLINE: Sweat, Algorithms, Sweat Glands, Wearable Electronic Devices. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Penta.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sweat is a biomarker-rich fluid with potential for continuous patient monitoring via wearable devices. However, biomarker concentrations vary with the sweat rate per gland, posing a challenge for sweat sensing. To address this, we propose an algorithm to compute both the number of active sweat glands and their individual sweat rates. We developed models of sweat glands and a discrete sweat-sensing device to sense sweat volume. Our algorithm estimates the number of active glands by decomposing the signal into patterns generated by the individual sweat glands, allowing for the calculation of individual sweat rates. We assessed the algorithm’s accuracy using synthetic datasets for varying physiological parameters (sweat rate and number of active sweat glands) and device layouts. The results show that device layout significantly affects accuracy, with error rates below 0.2% for low and medium sweat rates (below 0.2 nL min−1 per gland). However, the method is not suitable for high sweat rates. The suitable sweat rate range can be adapted to different needs through the choice of device. Based on our findings, we provide recommendations for optimal device layouts to improve accuracy in estimating active sweat glands. This is the first study to focus on estimating the sweat rate per gland, which essential for accurate biomarker concentration estimation and advancing sweat sensing towards clinical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SweatAlgorithmsSweat GlandsWearable Electronic DevicesHumansBiosensing TechniquesBiomarkers

Stichwörter der Autor:innen

discrete sweat sensing devicehealth monitoringsweat

Substanzen

Biomarkers

Autor:innen und Institutionen

  • Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands.
  • Mechanical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands.
  • Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands.

ORCID-Profile: Jelte R Haakma, Elisabetta Peri, Simona Turco, Jaap M J den Toonder, Massimo Mischi

Förderung

  • Penta

Zitieren

APA

Haakma, J. R., Peri, E., Turco, S., Pelssers, E., den Toonder, J. M. J., & Mischi, M. (2024). Estimation of the Number of Active Sweat Glands Through Discrete Sweat Sensing. Sensors. https://doi.org/10.3390/s24227187

Vancouver

Haakma JR, Peri E, Turco S, Pelssers E, den Toonder JMJ, Mischi M. Estimation of the Number of Active Sweat Glands Through Discrete Sweat Sensing. Sensors. 2024. doi:10.3390/s24227187

BibTeX
@article{Haakma2024,
  author = {Haakma, Jelte R and Peri, Elisabetta and Turco, Simona and Pelssers, Eduard and den Toonder, Jaap M J and Mischi, Massimo},
  title = {Estimation of the Number of Active Sweat Glands Through Discrete Sweat Sensing},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24227187}
}
Kostenlos starten →