EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access · CC BY 4.0

Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence

Raghad S Alsharidah iD, Razique Anwer iD, Maysoon Anwar Abdelhamid, Eman Amer Alanazi, Farah Mfwadh Alanazi, Haneen Fahaid Alanazi, Jumanah Naif Alotaibi, Lama Abdulaziz Alshathri iD, Renad Ali Alshehri iD, Rania Alsuhibani, Raghad H Majrashi iD

Biosensors · 2026

DOI: 10.3390/bios16090521 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Biosensors, 2026. Verfasst von Raghad S Alsharidah und 10 weiteren Autor:innen. Beteiligte Einrichtung: College of Medicine, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 13317-4233, Saudi Arabia. Hauptthemen laut MEDLINE: Sweat, Biosensing Techniques, Tumor Necrosis Factor-alpha, Interleukin-6. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Wearable sweat biosensors have emerged as a promising non-invasive approach for monitoring inflammatory biomarkers, offering an alternative to repeated blood sampling. This systematic review evaluated the current evidence on the detection of C-reactive protein (CRP), interleukin-6 (IL-6), and tumor necrosis factor-α (TNF-α) in sweat for infection and inflammatory disease monitoring.

Methods

Following PRISMA 2020 guidelines (PROSPERO: CRD420261371221), PubMed/MEDLINE, Scopus, Web of Science, IEEE Xplore, and Google Scholar were searched through April 2026. Human studies measuring CRP, IL-6, or TNF-α in sweat using wearable or biosensor-based platforms were included. Risk of bias and certainty of evidence were assessed using a modified Newcastle–Ottawa Scale/JBI checklist and GRADE.

Results

Thirteen studies (2020–2025, 5–80 participants) were included. CRP showed the most consistent sweat-serum agreement (r = 0.844) and good diagnostic performance in one inflammatory bowel disease cohort (AUC = 0.845). TNF-α demonstrated the highest diagnostic accuracy in a single longitudinal study (AUC = 0.962), whereas IL-6 showed moderate sweat-serum correlations (R2 = 0.60–0.72) but limited diagnostic discrimination. IL-6 and TNF-α were more consistently detected in passively collected eccrine sweat, although IL-6 was also successfully measured following pilocarpine iontophoresis in one study. Most studies had moderate methodological quality.

Conclusions

Sweat-based measurement of CRP, IL-6, and TNF-α is analytically feasible for non-invasive inflammatory biomarker monitoring. However, current evidence remains limited by small, heterogeneous studies, underscoring the need for standardized protocols and larger prospective clinical validation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SweatBiosensing TechniquesTumor Necrosis Factor-alphaInterleukin-6C-Reactive ProteinWearable Electronic DevicesHumansBiomarkersInflammation

Stichwörter der Autor:innen

C-reactive proteininfection detectioninterleukin-6sweat biosensorstumor necrosis factor-αwearable devices

Substanzen

BiomarkersTumor Necrosis Factor-alphaInterleukin-6C-Reactive Protein

Autor:innen und Institutionen

  • College of Medicine, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 13317-4233, Saudi Arabia.
  • Department of Pathology, College of Medicine, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 13317-4233, Saudi Arabia.

ORCID-Profile: Raghad S Alsharidah, Razique Anwer, Lama Abdulaziz Alshathri, Renad Ali Alshehri, Raghad H Majrashi

Zitieren

APA

Alsharidah, R. S., Anwer, R., Abdelhamid, M. A., Alanazi, E. A., Alanazi, F. M., Alanazi, H. F., Alotaibi, J. N., Alshathri, L. A., Alshehri, R. A., Alsuhibani, R., & Majrashi, R. H. (2026). Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence. Biosensors. https://doi.org/10.3390/bios16090521

Vancouver

Alsharidah RS, Anwer R, Abdelhamid MA, Alanazi EA, Alanazi FM, Alanazi HF, et al. Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence. Biosensors. 2026. doi:10.3390/bios16090521

BibTeX
@article{Alsharidah2026,
  author = {Alsharidah, Raghad S and Anwer, Razique and Abdelhamid, Maysoon Anwar and Alanazi, Eman Amer and Alanazi, Farah Mfwadh and Alanazi, Haneen Fahaid and Alotaibi, Jumanah Naif and Alshathri, Lama Abdulaziz and Alshehri, Renad Ali and Alsuhibani, Rania and Majrashi, Raghad H},
  title = {Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence},
  journal = {Biosensors},
  year = {2026},
  doi = {10.3390/bios16090521}
}
Kostenlos starten →