EUVIMEDEUVIMED entdecken
Crossref

An 800MΩ-Input-Impedance 95.3dB-DR Δ-ΔΣ AFE for Dry-Electrode Wearable EEG Recording

Yuying Li, Yijie Li, Hao Li, Zhiliang Hong, Jiawei Xu

IEEE Transactions on Biomedical Circuits and Systems · 2024

DOI: 10.1109/tbcas.2024.3374891 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2024. Verfasst von Yuying Li und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Electroencephalography, Wearable Electronic Devices, Electrodes, Electric Impedance. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Non-invasive, closed-loop brain modulation offers an accessible and cost-effective means of evaluating and modulating one's mental and physical well-being, such as Parkinson's disease, epilepsy, and sleep disorders. However, wearable EEG systems pose significant challenges for the analog front-end (AFE) circuits in view of µV-level EEG signals of interest, multiple sources of interference, and ill-defined skin contact. This paper presents a direct-digitization AFE tailored for dry-electrode scalp EEG recording, characterized by wide input dynamic range (DR) and high input impedance. The AFE utilizes a second-order 5-bit delta-delta sigma (Δ-ΔΣ) ADC to shape DC electrode offset (DEO) and low-frequency disturbances while retaining high accuracy. A non-inverting pseudo-differential instrumentation amplifier (IA) embedded in the ADC ensures high input impedance (Zin) and common-mode rejection ratio (CMRR). Fabricated in a standard 0.18-μm CMOS process, the AFE delivers 700-mVpp input signal range, 95.3-dB DR, 87-dB SNDR, and 800-MΩ input impedance at 50 Hz while consuming 88.4µW from a 1.2 V supply. The benefits of high DR and high input impedance have been validated by dry-electrode EEG measurement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroencephalographyWearable Electronic DevicesElectrodesElectric ImpedanceSignal Processing, Computer-AssistedHumansAmplifiers, ElectronicEquipment Design

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Li, Y., Li, Y., Li, H., Hong, Z., & Xu, J. (2024). An 800MΩ-Input-Impedance 95.3dB-DR Δ-ΔΣ AFE for Dry-Electrode Wearable EEG Recording. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2024.3374891

Vancouver

Li Y, Li Y, Li H, Hong Z, Xu J. An 800MΩ-Input-Impedance 95.3dB-DR Δ-ΔΣ AFE for Dry-Electrode Wearable EEG Recording. IEEE Transactions on Biomedical Circuits and Systems. 2024. doi:10.1109/tbcas.2024.3374891

BibTeX
@article{Li2024,
  author = {Li, Yuying and Li, Yijie and Li, Hao and Hong, Zhiliang and Xu, Jiawei},
  title = {An 800MΩ-Input-Impedance 95.3dB-DR Δ-ΔΣ AFE for Dry-Electrode Wearable EEG Recording},
  journal = {IEEE Transactions on Biomedical Circuits and Systems},
  year = {2024},
  doi = {10.1109/tbcas.2024.3374891}
}
Kostenlos starten →