Robot Calibration Sampling Data Optimization Method Based on Improved Robot Observability Metrics and Binary Simulated Annealing Algorithm
Sensors · 24.09.2024 · 24 (19) · 6171
DOI: 10.3390/s24196171 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 24.09.2024. Verfasst von Huakun Jia und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China, Taishan Scholar Program of Shandong Province in China.
Abstract (Originalsprache)
As the societal demand for precision in industrial robot operations increases, calibration can enhance the end-effector positioning accuracy of robots. Sampling data optimization plays an important role in improving the calibration effect. In this study, a robot calibration sampling point optimization method based on improved robot observability metrics and a Binary Simulated Annealing Algorithm is proposed. Initially, a robot kinematic model based on the Product of Exponentials (POE) model and a generalized error model is established. By utilizing the least squares method, the ideal pose transformation relationship between the robot’s base coordinate system and the laser tracker measurement coordinate system is derived, resulting in an error calibration model based on spatial single points. An improved robot observability metric combined with the Binary Simulated Annealing Algorithm (BSAA) is introduced to optimize the selection of calibration sampling data. Finally, the robot’s parameter errors are obtained using a nonlinear least squares method. Experimental results demonstrate that the average end-effector positioning error of the robot after calibration can be reduced from 0.356 mm to 0.254 mm using this method.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China.
ORCID-Profile: Huakun Jia
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program of China
- Taishan Scholar Program of Shandong Province in China
- Young Elite Scientists Sponsorship Program by CAST
Zitieren
APA
Jia, H., Zeng, H., Zhang, J., Wang, X., Lu, Y., & Yu, L. (2024). Robot Calibration Sampling Data Optimization Method Based on Improved Robot Observability Metrics and Binary Simulated Annealing Algorithm. Sensors, 24(19), 6171. https://doi.org/10.3390/s24196171
Vancouver
Jia H, Zeng H, Zhang J, Wang X, Lu Y, Yu L. Robot Calibration Sampling Data Optimization Method Based on Improved Robot Observability Metrics and Binary Simulated Annealing Algorithm. Sensors. 2024;24(19):6171. doi:10.3390/s24196171
BibTeX
@article{Jia2024,
author = {Jia, Huakun and Zeng, Hanbo and Zhang, Jiyan and Wang, Xiangyang and Lu, Yang and Yu, Liandong},
title = {Robot Calibration Sampling Data Optimization Method Based on Improved Robot Observability Metrics and Binary Simulated Annealing Algorithm},
journal = {Sensors},
year = {2024},
volume = {24},
number = {19},
pages = {6171},
doi = {10.3390/s24196171}
}
EUVIMED