EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Center of Pressure Measurement Accuracy via Insoles with a Reduced Pressure Sensor Number during Gaits

Philip X Fuchs iD, Wei-Han Chen iD, Tzyy-Yuang Shiang

Sensors · 2024

DOI: 10.3390/s24154918 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Philip X Fuchs und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Athletic Performance, National Taiwan Normal University, No. 88, Section 4, Tingzhou Road, Wenshan District, Taipei City 116, Taiwan. Hauptthemen laut MEDLINE: Pressure, Gait, Walking, Shoes. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Taiwan Normal University (NTNU).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The objective was to compare simplified pressure insoles integrating different sensor numbers and to identify a promising range of sensor numbers for accurate center of pressure (CoP) measurement. Twelve participants wore a 99-sensor Pedar-X insole (100 Hz) during walking, jogging, and running. Eight simplified layouts were simulated, integrating 3–17 sensors. Concordance correlation coefficients (CCC) and root mean square errors (RMSE) between the original and simplified layouts were calculated for time-series mediolateral (ML) and anteroposterior (AP) CoP. Differences between layouts and between gait types were assessed via ANOVA and Friedman test. Concordance between the original and simplified layouts varied across layouts and gaits (CCC: 0.43–0.98; χ(7)2 ≥ 34.94, p < 0.001). RMSEML and RMSEAP [mm], respectively, were smaller in jogging (5 ± 2, 15 ± 9) than in walking (8 ± 2, 22 ± 4) and running (7 ± 4, 20 ± 7) (ηp2: 0.70–0.83, p < 0.05). Only layouts with 11+ sensors achieved CCC ≥ 0.80 in all tests across gaits. The 13-sensor layout achieved CCC ≥ 0.95 with 95% confidence, representing the most promising compromise between sensor number and CoP accuracy. Future research may refine sensor placement, suggesting the use of 11–13 sensors. For coaches, therapists, and applied sports scientists, caution is recommended when using insoles with nine or fewer sensors. Consulting task-specific validation results for the intended products is advisable.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PressureGaitWalkingShoesHumansMaleFemaleAdultRunningYoung AdultFoot OrthosesJoggingBiomechanical Phenomena

Stichwörter der Autor:innen

analysisassessmentbiomechanicskineticstechnology

Autor:innen und Institutionen

  • Department of Athletic Performance, National Taiwan Normal University, No. 88, Section 4, Tingzhou Road, Wenshan District, Taipei City 116, Taiwan.
  • Department of Physical Education and Sport Sciences, National Taiwan Normal University, No. 162, Section 1, Heping East Road, Da'an District, Taipei City 106, Taiwan.
  • Department of Physical Education and Kinesiology, National Dong Hwa University, No. 1, Section 2, Da Hsueh Road, Shoufeng District, Hualian City 974301, Taiwan.

ORCID-Profile: Philip X Fuchs, Wei-Han Chen

Förderung

  • National Taiwan Normal University (NTNU)

Zitieren

APA

Fuchs, P. X., Chen, W. H., & Shiang, T. Y. (2024). Center of Pressure Measurement Accuracy via Insoles with a Reduced Pressure Sensor Number during Gaits. Sensors. https://doi.org/10.3390/s24154918

Vancouver

Fuchs PX, Chen WH, Shiang TY. Center of Pressure Measurement Accuracy via Insoles with a Reduced Pressure Sensor Number during Gaits. Sensors. 2024. doi:10.3390/s24154918

BibTeX
@article{Fuchs2024,
  author = {Fuchs, Philip X and Chen, Wei-Han and Shiang, Tzyy-Yuang},
  title = {Center of Pressure Measurement Accuracy via Insoles with a Reduced Pressure Sensor Number during Gaits},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24154918}
}
Kostenlos starten →