Ultrashort-Echo-Time MRI of the Disco-Vertebral Junction: Modulation of Image Contrast via Echo Subtraction and Echo Times
Sensors · 2024
DOI: 10.3390/s24175842 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Karen C Chen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, VA San Diego Healthcare System, San Diego, CA 92161, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIAMS NIH HHS, General Electric Healthcare, NIH HHS.
Abstract (Originalsprache)
Introduction
The disco-vertebral junction (DVJ) of the lumbar spine contains thin structures with short T2 values, including the cartilaginous endplate (CEP) sandwiched between the bony vertebral endplate (VEP) and the nucleus pulposus (NP). We previously demonstrated that ultrashort-echo-time (UTE) MRI, compared to conventional MRI, is able to depict the tissues at the DVJ with improved contrast. In this study, we sought to further optimize UTE MRI by characterizing the contrast-to-noise ratio (CNR) of these tissues when either single echo or echo subtraction images are used and with varying echo times (TEs).
Methods
In four cadaveric lumbar spines, we acquired 3D Cones (a UTE sequence) images at varying TEs from 0.032 ms to 16 ms. Additionally, spin echo T1- and T2-weighted images were acquired. The CNRs of CEP-NP and CEP-VEP were measured in all source images and 3D Cones echo subtraction images.
Results
In the spin echo images, it was challenging to distinguish the CEP from the VEP, as both had low signal intensity. However, the 3D Cones source images at the shortest TE of 0.032 ms provided an excellent contrast between the CEP and the VEP. As the TE increased, the contrast decreased in the source images. In contrast, the 3D Cones echo subtraction images showed increasing CNR values as the second TE increased, reaching statistical significance when the second TE was above 10 ms (p < 0.05).
Conclusions
Our study highlights the feasibility of incorporating UTE MRI for the evaluation of the DVJ and its advantages over conventional spin echo sequences for improving the contrast between the CEP and adjacent tissues. Additionally, modulation of the contrast for the target tissues can be achieved using either source images or subtraction images, as well as by varying the echo times.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, VA San Diego Healthcare System, San Diego, CA 92161, USA.
- Department of Radiology, Siriraj Hospital, Bangkok 10700, Thailand.
- Department of Radiology, University of California-San Diego, La Jolla, CA 92093, USA.
ORCID-Profile: Palanan Siriwananrangsun, Won C Bae
Förderung
- NIAMS NIH HHS
- General Electric Healthcare
- NIH HHS
- NIH NIAMS
- General Electric Healthcare for MRI
Zitieren
APA
Chen, K. C., Siriwananrangsun, P., & Bae, W. C. (2024). Ultrashort-Echo-Time MRI of the Disco-Vertebral Junction: Modulation of Image Contrast via Echo Subtraction and Echo Times. Sensors. https://doi.org/10.3390/s24175842
Vancouver
Chen KC, Siriwananrangsun P, Bae WC. Ultrashort-Echo-Time MRI of the Disco-Vertebral Junction: Modulation of Image Contrast via Echo Subtraction and Echo Times. Sensors. 2024. doi:10.3390/s24175842
BibTeX
@article{Chen2024,
author = {Chen, Karen C and Siriwananrangsun, Palanan and Bae, Won C},
title = {Ultrashort-Echo-Time MRI of the Disco-Vertebral Junction: Modulation of Image Contrast via Echo Subtraction and Echo Times},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24175842}
}
EUVIMED