EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Utility of Calibrating Wearable Sensors before Quantifying Infant Leg Movements

Jinseok Oh iD, Gerald E Loeb iD, Beth A Smith iD

Sensors · 2024

DOI: 10.3390/s24175736 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Jinseok Oh und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Developmental-Behavioral Pediatrics, Children's Hospital Los Angeles, Los Angeles, CA 90027, USA. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Movement, Leg, Algorithms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIDA NIH HHS, National Institute on Drug Abuse.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

While interest in using wearable sensors to measure infant leg movement is increasing, attention should be paid to the characteristics of the sensors. Specifically, offset error in the measurement of gravitational acceleration (g) is common among commercially available sensors. In this brief report, we demonstrate how we measured the offset and other errors in three different off-the-shelf wearable sensors available to professionals and how they affected a threshold-based movement detection algorithm for the quantification of infant leg movement. We describe how to calibrate and correct for these offsets and how conducting this improves the reproducibility of results across sensors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesMovementLegAlgorithmsHumansInfantCalibrationReproducibility of ResultsMonitoring, PhysiologicAcceleration

Stichwörter der Autor:innen

calibrationinertial measurement unit (IMU)movement quantificationoffset errorreproducibilitywearable sensors

Autor:innen und Institutionen

  • Division of Developmental-Behavioral Pediatrics, Children's Hospital Los Angeles, Los Angeles, CA 90027, USA.
  • Alfred E. Mann Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA 90089, USA.
  • Department of Pediatrics, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, USA.
  • Developmental Neuroscience and Neurogenetics Program, The Saban Research Institute, Children's Hospital Los Angeles, Los Angeles, CA 90027, USA.

ORCID-Profile: Jinseok Oh, Gerald E Loeb, Beth A Smith

Förderung

  • NIDA NIH HHS
  • National Institute on Drug Abuse

Zitieren

APA

Oh, J., Loeb, G. E., & Smith, B. A. (2024). The Utility of Calibrating Wearable Sensors before Quantifying Infant Leg Movements. Sensors. https://doi.org/10.3390/s24175736

Vancouver

Oh J, Loeb GE, Smith BA. The Utility of Calibrating Wearable Sensors before Quantifying Infant Leg Movements. Sensors. 2024. doi:10.3390/s24175736

BibTeX
@article{Oh2024,
  author = {Oh, Jinseok and Loeb, Gerald E and Smith, Beth A},
  title = {The Utility of Calibrating Wearable Sensors before Quantifying Infant Leg Movements},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24175736}
}
Kostenlos starten →