Portable Sensors for Dynamic Exposure Assessments in Urban Environments: State of the Science
Sensors · 2024-08-30 · 24 (17) · 5653
DOI: 10.3390/s24175653 ↗At a glance
Journal article in Sensors, published online on 2024-08-30. Written by Jelle Hofman and 5 co-authors. Institution: Environmental Intelligence Unit, Flemish Institute for Technological Research (VITO), Vlasmeer 5, 2400 Mol, Belgium. Major MEDLINE topics: Environmental Monitoring. Cited 10 times so far (Crossref); 78 references. The full text is freely available (open access, CC BY 4.0). Funded by: European Union's Horizon 2020 Research and Innovation Program (RI-URBANS), Innovative Public Procurement Program (PIO), European Union’s Horizon 2020 Research and Innovation Program.
Abstract (original language)
This study presents a fit-for-purpose lab and field evaluation of commercially available portable sensor systems for PM, NO2, and/or BC. The main aim of the study is to identify portable sensor systems that are capable of reliably quantifying dynamic exposure gradients in urban environments. After an initial literature and market study resulting in 39 sensor systems, 10 sensor systems were ultimately purchased and benchmarked under laboratory and real-word conditions. We evaluated the comparability to reference analyzers, sensor precision, and sensitivity towards environmental confounders (temperature, humidity, and O3). Moreover, we evaluated if the sensor accuracy can be improved by applying a lab or field calibration. Because the targeted application of the sensor systems under evaluation is mobile monitoring, we conducted a mobile field test in an urban environment to evaluate the GPS accuracy and potential impacts from vibrations on the resulting sensor signals. Results of the considered sensor systems indicate that out-of-the-box performance is relatively good for PM (R2 = 0.68–0.9, Uexp = 16–66%, BSU = 0.1–0.7 µg/m3) and BC (R2 = 0.82–0.83), but maturity of the tested NO2 sensors is still low (R2 = 0.38–0.55, Uexp = 111–614%) and additional efforts are needed in terms of signal noise and calibration, as proven by the performance after multilinear calibration (R2 = 0.75–0.83, Uexp = 37–44%)). The horizontal accuracy of the built-in GPS was generally good, achieving
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Environmental Intelligence Unit, Flemish Institute for Technological Research (VITO), Vlasmeer 5, 2400 Mol, Belgium.
- Flanders Environmental Agency (VMM), Kronenburgstraat 45, 2000 Antwerp, Belgium.
ORCID profiles: Jelle Hofman, Borislav Lazarov, Christophe Stroobants, Martine Van Poppel
Funding
- European Union's Horizon 2020 Research and Innovation Program (RI-URBANS)
- Innovative Public Procurement Program (PIO)
- European Union’s Horizon 2020 Research and Innovation Program
Cite
APA
Hofman, J., Lazarov, B., Stroobants, C., Elst, E., Smets, I., & Van Poppel, M. (2024). Portable Sensors for Dynamic Exposure Assessments in Urban Environments: State of the Science. Sensors, 24(17), 5653. https://doi.org/10.3390/s24175653
Vancouver
Hofman J, Lazarov B, Stroobants C, Elst E, Smets I, Van Poppel M. Portable Sensors for Dynamic Exposure Assessments in Urban Environments: State of the Science. Sensors. 2024;24(17):5653. doi:10.3390/s24175653
BibTeX
@article{Hofman2024,
author = {Hofman, Jelle and Lazarov, Borislav and Stroobants, Christophe and Elst, Evelyne and Smets, Inge and Van Poppel, Martine},
title = {Portable Sensors for Dynamic Exposure Assessments in Urban Environments: State of the Science},
journal = {Sensors},
year = {2024},
volume = {24},
number = {17},
pages = {5653},
doi = {10.3390/s24175653}
}
EUVIMED