Validity and Test–Retest Reliability of Spatiotemporal Running Parameter Measurement Using Embedded Inertial Measurement Unit Insoles
Sensors · 2024
DOI: 10.3390/s24165435 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Louis Riglet und 7 weiteren Autor:innen. Beteiligte Einrichtung: CHU Dijon-Bourgogne, Centre d'Investigation Clinique, Module Plurithématique, Plateforme d'Investigation Technologique, 21000 Dijon, France. Hauptthemen laut MEDLINE: Running, Gait. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DigitSole SAS.
Abstract (Originalsprache)
Running is the basis of many sports and has highly beneficial effects on health. To increase the understanding of running, DSPro® insoles were developed to collect running parameters during tasks. However, no validation has been carried out for running gait analysis. The aims of this study were to assess the test–retest reliability and criterion validity of running gait parameters from DSPro® insoles compared to a motion-capture system. Equipped with DSPro® insoles, a running gait analysis was performed on 30 healthy participants during overground and treadmill running using a motion-capture system. Using an intraclass correlation coefficient (ICC), the criterion validity and test–retest reliability of spatiotemporal parameters were calculated. The test–retest reliability shows moderate to excellent ICC values (ICC > 0.50) except for propulsion time during overground running at a fast speed with the motion-capture system. The criterion validity highlights a validation of running parameters regardless of speeds (ICC > 0.70). This present study validates the good criterion validity and test–retest reliability of DSPro® insoles for measuring spatiotemporal running gait parameters. Without the constraints of a 3D motion-capture system, such insoles seem to be helpful and relevant for improving the care management of active patients or following running performance in sports contexts.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- CHU Dijon-Bourgogne, Centre d'Investigation Clinique, Module Plurithématique, Plateforme d'Investigation Technologique, 21000 Dijon, France.
- INSERM, CIC 1432, Module Plurithématique, Plateforme d'Investigation Technologique, 21000 Dijon, France.
- Zhortech SAS, 54000 Nancy, France.
- INSERM, UMR1093-CAPS, Université Bourgogne Franche-Comté, UB, 21000 Dijon, France.
- Rheumatology Department, CHU Dijon-Bourgogne, 21000 Dijon, France.
- Collaborative Research Network STARTER (Innovative Strategies and Artificial Intelligence for Motor Function Rehabilitation and Autonomy Preservation), 21000 Dijon, France.
ORCID-Profile: Paul Ornetti, Mathieu Gueugnon
Förderung
- DigitSole SAS
Zitieren
APA
Riglet, L., Orliac, B., Delphin, C., Leonard, A., Eby, N., Ornetti, P., Laroche, D., & Gueugnon, M. (2024). Validity and Test–Retest Reliability of Spatiotemporal Running Parameter Measurement Using Embedded Inertial Measurement Unit Insoles. Sensors. https://doi.org/10.3390/s24165435
Vancouver
Riglet L, Orliac B, Delphin C, Leonard A, Eby N, Ornetti P, et al. Validity and Test–Retest Reliability of Spatiotemporal Running Parameter Measurement Using Embedded Inertial Measurement Unit Insoles. Sensors. 2024. doi:10.3390/s24165435
BibTeX
@article{Riglet2024,
author = {Riglet, Louis and Orliac, Baptiste and Delphin, Corentin and Leonard, Audrey and Eby, Nicolas and Ornetti, Paul and Laroche, Davy and Gueugnon, Mathieu},
title = {Validity and Test–Retest Reliability of Spatiotemporal Running Parameter Measurement Using Embedded Inertial Measurement Unit Insoles},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24165435}
}