Combined Impact of Heart Rate Sensor Placements with Respiratory Rate and Minute Ventilation on Oxygen Uptake Prediction
Sensors · 2024
DOI: 10.3390/s24165412 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Zhihui Lu und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of China Football Sports, Beijing Sport University, Beijing 100084, China. Hauptthemen laut MEDLINE: Heart Rate, Respiratory Rate, Oxygen Consumption. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
Oxygen uptake (V˙O2) is an essential metric for evaluating cardiopulmonary health and athletic performance, which can barely be directly measured. Heart rate (HR) is a prominent physiological indicator correlated with V˙O2 and is often used for indirect V˙O2 prediction. This study investigates the impact of HR placement on V˙O2 prediction accuracy by analyzing HR data combined with the respiratory rate (RESP) and minute ventilation (V˙E) from three anatomical locations: the chest; arm; and wrist. Twenty-eight healthy adults participated in incremental and constant workload cycling tests at various intensities. Data on V˙O2, RESP, V˙E, and HR were collected and used to develop a neural network model for V˙O2 prediction. The influence of HR position on prediction accuracy was assessed via Bland–Altman plots, and model performance was evaluated by mean absolute error (MAE), coefficient of determination (R2), and mean absolute percentage error (MAPE). Our findings indicate that HR combined with RESP and V˙E (V˙O2HR+RESP+V˙E) produces the most accurate V˙O2 predictions (MAE: 165 mL/min, R2: 0.87, MAPE: 15.91%). Notably, as exercise intensity increases, the accuracy of V˙O2 prediction decreases, particularly within high-intensity exercise. The substitution of HR with different anatomical sites significantly impacts V˙O2 prediction accuracy, with wrist placement showing a more profound effect compared to arm placement. In conclusion, this study underscores the importance of considering HR placement in V˙O2 prediction models, with RESP and V˙E serving as effective compensatory factors. These findings contribute to refining indirect V˙O2 estimation methods, enhancing their predictive capabilities across different exercise intensities and anatomical placements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of China Football Sports, Beijing Sport University, Beijing 100084, China.
- Exercise Science School, Beijing Sport University, Beijing 100084, China.
- School of Sports Engineering, Beijing Sport University, Beijing 100084, China.
- Key Laboratory of Exercise and Physical Fitness, Ministry of Education, Beijing Sport University, Beijing 100084, China.
- Beijing Sports Nutrition Engineering Research Center, Beijing 100084, China.
ORCID-Profile: Kuan Tao
Förderung
- National Key Research and Development Program of China
- Fundamental Research Funds for the Central Universities
Zitieren
APA
Lu, Z., Yang, J., Tao, K., Li, X., Xu, H., & Qiu, J. (2024). Combined Impact of Heart Rate Sensor Placements with Respiratory Rate and Minute Ventilation on Oxygen Uptake Prediction. Sensors. https://doi.org/10.3390/s24165412
Vancouver
Lu Z, Yang J, Tao K, Li X, Xu H, Qiu J. Combined Impact of Heart Rate Sensor Placements with Respiratory Rate and Minute Ventilation on Oxygen Uptake Prediction. Sensors. 2024. doi:10.3390/s24165412
BibTeX
@article{Lu2024,
author = {Lu, Zhihui and Yang, Junchao and Tao, Kuan and Li, Xiangxin and Xu, Haoqi and Qiu, Junqiang},
title = {Combined Impact of Heart Rate Sensor Placements with Respiratory Rate and Minute Ventilation on Oxygen Uptake Prediction},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24165412}
}
EUVIMED