Using Flexible-Printed Piezoelectric Sensor Arrays to Measure Plantar Pressure during Walking for Sarcopenia Screening
Sensors · 11.08.2024 · 24 (16) · 5189
DOI: 10.3390/s24165189 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 11.08.2024. Verfasst von Shulang Han und 8 weiteren Autor:innen. Beteiligte Einrichtung: College of Mechanical Engineering, Sichuan University, Chengdu 610065, China. Hauptthemen laut MEDLINE: Sarcopenia, Pressure, Walking, Wearable Electronic Devices. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Sichuan Province science and technology innovation base project, Major Research Programs of Science & Technology Department of Sichuan Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Sarcopenia is an age-related syndrome characterized by the loss of skeletal muscle mass and function. Community screening, commonly used in early diagnosis, usually lacks features such as real-time monitoring, low cost, and convenience. This study introduces a promising approach to sarcopenia screening by dynamic plantar pressure monitoring. We propose a wearable flexible-printed piezoelectric sensing array incorporating barium titanate thin films. Utilizing a flexible printer, we fabricate the array with enhanced compressive strength and measurement range. Signal conversion circuits convert charge signals of the sensors into voltage signals, which are transmitted to a mobile phone via Bluetooth after processing. Through cyclic loading, we obtain the average voltage sensitivity (4.844 mV/kPa) of the sensing array. During a 6 m walk, the dynamic plantar pressure features of 51 recruited participants are extracted, including peak pressures for both sarcopenic and control participants before and after weight calibration. Statistical analysis discerns feature significance between groups, and five machine learning models are employed to screen for sarcopenia with the collected features. The results show that the features of dynamic plantar pressure have great potential in early screening of sarcopenia, and the Support Vector Machine model after feature selection achieves a high accuracy of 93.65%. By combining wearable sensors with machine learning techniques, this study aims to provide more convenient and effective sarcopenia screening methods for the elderly.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Mechanical Engineering, Sichuan University, Chengdu 610065, China.
- College of Mechanical and Electrical Engineering, Chengdu University of Technology, Chengdu 610059, China.
- College of Architecture and Environment, Sichuan University, Chengdu 610065, China.
- Chongqing Municipality Clinical Research Center for Geriatric Diseases, Chongqing University Three Gorges Hospital, School of Medicine, Chongqing University, Chongqing 404000, China.
- Department of Senile Medical, The Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou 646000, China.
- Department of Geriatrics, West China Hospital, Sichuan University, Chengdu 610041, China.
ORCID-Profile: Yu Chen
Förderung
- Sichuan Province science and technology innovation base project
- Major Research Programs of Science & Technology Department of Sichuan Province
- National Natural Science Foundation of China
- Project of Sichuan Luzhou Science and Technology Bureau
- Major Research Programs of the Science & Technology Department of Sichuan Province
Zitieren
APA
Han, S., Xiao, Q., Liang, Y., Chen, Y., Yan, F., Chen, H., Yue, J., Tian, X., & Xiong, Y. (2024). Using Flexible-Printed Piezoelectric Sensor Arrays to Measure Plantar Pressure during Walking for Sarcopenia Screening. Sensors, 24(16), 5189. https://doi.org/10.3390/s24165189
Vancouver
Han S, Xiao Q, Liang Y, Chen Y, Yan F, Chen H, et al. Using Flexible-Printed Piezoelectric Sensor Arrays to Measure Plantar Pressure during Walking for Sarcopenia Screening. Sensors. 2024;24(16):5189. doi:10.3390/s24165189
BibTeX
@article{Han2024,
author = {Han, Shulang and Xiao, Qing and Liang, Ying and Chen, Yu and Yan, Fei and Chen, Hui and Yue, Jirong and Tian, Xiaobao and Xiong, Yan},
title = {Using Flexible-Printed Piezoelectric Sensor Arrays to Measure Plantar Pressure during Walking for Sarcopenia Screening},
journal = {Sensors},
year = {2024},
volume = {24},
number = {16},
pages = {5189},
doi = {10.3390/s24165189}
}
EUVIMED